HAL options after Windows XP or Windows Server 2003 Setup

HAL options after Windows XP or Windows Server 2003 Setup

<script type="text/javascript">function loadTOCNode(){}</script>
Article ID:309283
Last Review:May 13, 2008
Revision:9.0
This article was previously published under Q309283
<script type="text/javascript"> var sectionFilter = "type != 'notice' && type != 'securedata' && type != 'querywords'"; var tocArrow = "/library/images/support/kbgraphics/public/en-us/downarrow.gif"; var depthLimit = 10; var depth3Limit = 10; var depth4Limit = 5; var depth5Limit = 3; var tocEntryMinimum = 1; </script> <script src="/common/script/gsfx/kbtoc.js?11" type="text/javascript"></script>

SUMMARY

<script type="text/javascript">loadTOCNode(1, 'summary');</script>
This article describes hardware abstraction layer (HAL) options that are listed in Device Manager after you run Windows XP Setup or Windows Server 2003 Setup. The article also discusses supportability issues that involve HALs in Sysprep images.

Back to the top

MORE INFORMATION

<script type="text/javascript">loadTOCNode(1, 'moreinformation');</script>
Windows XP Device Manager and Windows Server 2003 Device Manager list limited choices for changing your HAL type when you click Update Driver. Microsoft Windows 2000 Device Manager lets you select any HAL type.

If you select an incorrect HAL, you may not be able to start Windows 2000, or you may have other issues. Although the selections are now limited, you should change the HAL only if you are sure that the selected HAL works on your system. The options that are presented here are known to be compatible with most systems. However, a few systems may experience problems.

When you install the following HALs on a Windows XP-based or Windows Server 2003-based computer, the following device manager HAL options appear:
 "Standard PC," Non-ACPI PIC HAL (Hal.dll)
Standard PC
 "MPS Uniprocessor PC," Non-ACPI APIC UP HAL (Halapic.dll)
Standard PC
MPS Uniprocessor
MPS Multiprocessor
 "MPS Multiprocessor PC," Non-ACPI APIC MP HAL (Halmps.dll)
Standard PC
MPS Multiprocessor
 "Advanced Configuration and Power Interface (ACPI) PC," ACPI PIC HAL (Halacpi.dll)
Standard PC
Advanced Configuration and Power Interface (ACPI) PC
 "ACPI Uniprocessor PC," ACPI APIC UP HAL (Halaacpi.dll)
Standard PC
Advanced Configuration and Power Interface (ACPI) PC
ACPI Uniprocessor
ACPI Multiprocessor
 "ACPI Multiprocessor PC," ACPI APIC MP HAL (Halmacpi.dll)
Standard PC
Advanced Configuration and Power Interface (ACPI) PC
ACPI Multiprocessor
MPS Multiprocessor
Notes
A common symptom when deploying the incorrect image to a computer is that the Sysprep image stops responding on restart or reports the following error message:
Stop 0x0000007b
If an incorrect HAL is forced during Setup or by using a System Preparation Image (Sysprep), you can see the correct list of HALs only if you perform a new installation of Windows XP or Windows Server 2003. You cannot change to a HAL other than what is listed in Device Manager.
Device Manager does not permit the change from a Non-ACPI HAL to an ACPI HAL. You must use a new install of Windows XP or Windows Server 2003 for this kind of change. Change from an ACPI HAL to a Non-ACPI HAL only for troubleshooting purposes.
On Windows XP and later versions, the ACPI Uniprocessor HAL and the MPS Uniprocessor HAL recognize the existence of more than one processor and report the MP ID. Plug and Play detects that the computer devnode's hardware ID list has changed and moves the devnode back through the "found new hardware" detection process. Therefore, when you add a second processor, the MP files (HAL and kernels) are automatically installed, and you do not have to manually update the driver in Device Manager.
Microsoft does not support running a HAL other than the HAL that Windows Setup would typically install on the computer. For example, running a PIC HAL on an APIC computer is not supported. Although this configuration may appear to work, Microsoft does not test this configuration and you may have performance and interrupt issues. Microsoft also does not support swapping out the files that are used by the HAL to manually change HAL types.
Microsoft recommends that you switch HALs for troubleshooting purposes only or to workaround a hardware problem.
When you create a Sysprep image, the image must contain the correct HAL type for the target computer. The following list describes the computers that you can deploy a particular Sysprep image to based on the HAL type in the source computer:
You can deploy a Sysprep image created on a computer that uses a Standard PC, Non-ACPI PIC HAL (Hal.dll) to a computer that uses the following HAL types:
Standard PC, Non-ACPI PIC HAL (Hal.dll)
You can deploy a Sysprep image created on a computer that uses an Advanced Configuration and Power Interface (ACPI) PC, ACPI PIC HAL (Halacpi.dll) to a computer that uses the following HAL types:
Advanced Configuration and Power Interface (ACPI) PC, ACPI PIC HAL (Halacpi.dll)
You can deploy a Sysprep image created on a computer that uses a MPS Uniprocessor PC, Non-ACPI APIC UP HAL (Halapic.dll) to a computer that uses the following HAL types:
MPS Uniprocessor PC, Non-ACPI APIC UP HAL (Halapic.dll)
MPS Multiprocessor PC, Non-ACPI APIC MP HAL (Halmps.dll)
You can deploy a Sysprep image created on a computer that uses a MPS Multiprocessor PC, Non-ACPI APIC MP HAL (Halmps.dll) to a computer that uses the following HAL types:
MPS Multiprocessor PC, Non-ACPI APIC MP HAL (Halmps.dll)
MPS Uniprocessor PC, Non-ACPI APIC UP HAL (Halapic.dll)
You can deploy a Sysprep image created on a computer that uses an ACPI Uniprocessor PC, ACPI APIC UP HAL (Halaacpi.dll) to a computer that uses the following HAL types:
ACPI Uniprocessor PC, ACPI APIC UP HAL (Halaacpi.dll)
ACPI Multiprocessor PC, ACPI APIC MP HAL (Halmacpi.dll)
You can deploy a Sysprep image created on a computer that uses an ACPI Multiprocessor PC, ACPI APIC MP HAL (Halmacpi.dll) to a computer that uses the following HAL types:
ACPI Multiprocessor PC, ACPI APIC MP HAL (Halmacpi.dll)
ACPI Uniprocessor PC, ACPI APIC UP HAL (Halaacpi.dll)
Note Currently, the options in Device Manager do not list an APIC version of the HAL when you change the HAL on an APIC system. Although the PIC HAL that is installed may work, you can select the preferred APIC version after you install a hotfix for computers that are running Windows Server 2003 with Service Pack 1.

For more information about the hotfix for Windows Server 2003 Service Pack 1, click the following article number to view the article in the Microsoft Knowledge Base:
923425 (http://support.microsoft.com/kb/923425/) You do not have the option to downgrade to a hardware abstraction layer that is set up to use a single-processor advanced programmable interrupt controller when you try to change the computer type by using Device Manager in Windows Server 2003

Back to the top

About UpdateUPHal

<script type="text/javascript">loadTOCNode(2, 'moreinformation');</script> UpdateUPHal was designed for the following scenarios.
Scenario 1
<script type="text/javascript">loadTOCNode(3, 'moreinformation');</script>
Source computer: MPS Multiprocessor (NON-ACPI APIC MP)
Destination computer: MPS Uniprocessor (NON-ACPI APIC UP)
To force the ACPI Uniprocessor HAL, use the following entry:
UpdateUPHal=MPS_UP, %windir%/inf/hal.inf
Scenario 2
<script type="text/javascript">loadTOCNode(3, 'moreinformation');</script>
Source computer: ACPI Multiprocessor (ACPI APIC MP)
Destination computer: ACPI Uniprocessor (ACPI APIC UP)
To force the Uniprocessor HAL, use the following entry:
UpdateUPHal=ACPIAPIC_UP, %windir%/inf/hal.inf
In this scenario, an easier solution is to create the image on the ACPI Uniprocessor computer. Windows XP and Windows Server 2003 will automatically install the ACPI Multiprocessor HAL if the computer supports it.

Back to the top

About UpdateHal

<script type="text/javascript">loadTOCNode(2, 'moreinformation');</script> UpdateHal was designed for the following scenarios.
Scenario 1
<script type="text/javascript">loadTOCNode(3, 'moreinformation');</script>
Source computer: MPS Uniprocessor (NON-ACPI APIC UP)
Destination computer: MPS Multiprocessor (NON-ACPI APIC MP)
In this scenario, use the following entry:
UpdateHal=MPS_MP, %windir%/inf/hal.inf
Note This entry is required only for Windows 2000 Server. Windows XP and Windows Server 2003 automatically upgrade to the MPS Multiprocessor HAL.
Scenario 2
<script type="text/javascript">loadTOCNode(3, 'moreinformation');</script>
Source computer: ACPI Uniprocessor (ACPI APIC UP)
Destination computer: ACPI Multiprocessor (ACPI APIC MP)
In this scenario, use the following entry:
UpdateHal=ACPIAPIC_MP, %windir%/inf/hal.inf
Note This entry is required only for Windows 2000 Server. Windows XP and Windows Server 2003 automatically upgrade to the ACPI Multiprocessor HAL.

For more information about how to force a HAL, click the following article number to view the article in the Microsoft Knowledge Base:
299340 (http://support.microsoft.com/kb/299340/) How to force a Hardware Abstraction Layer during an upgrade or an installation of Windows XP
For more information about how to reinstall Windows XP, click the following article number to view the article in the Microsoft Knowledge Base:
315341 (http://support.microsoft.com/kb/315341/) How to perform an in-place upgrade (reinstallation) of Windows XP

Back to the top


APPLIES TO
Microsoft Windows Server 2003, 64-Bit Datacenter Edition
Microsoft Windows Server 2003, Enterprise x64 Edition
Microsoft Windows Server 2003, Datacenter Edition (32-bit x86)
Microsoft Windows Server 2003, Enterprise Edition (32-bit x86)
Microsoft Windows Server 2003, Standard Edition (32-bit x86)
Microsoft Windows Server 2003, Web Edition
Microsoft Windows XP Home Edition
Microsoft Windows XP Professional
Microsoft Windows XP Tablet PC Edition
Microsoft Windows Small Business Server 2003 Premium Edition
Microsoft Windows Small Business Server 2003 Standard Edition

Back to the top

Keywords: 
kbenv kbinfo KB309283

Back to the top

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值