hp用HP Array Configuration Utility CLI 7.73-1.0
hp的官方有download
软件包是
tencent:/home/robin/test/io # rpm -qa | grep hp
hpacucli-7.73-1
今天又用了一下:
test:/home/robin # hpacucli
HP Array Configuration Utility CLI 7.73-1.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> controller all show
Smart Array E200i in Slot 0 (sn: PR6BMU5633 )
=> controller slot=0 array all show
Smart Array E200i in Slot 0
array A (SAS, Unused Space: 0 MB)
=> controller slot=0 physicaldrive all show
Smart Array E200i in Slot 0
array A
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
=> controller slot=0 logicaldrive all show
Smart Array E200i in Slot 0
array A
logicaldrive 1 (136.7 GB, RAID 1+0, OK)
=> quit
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/82392/viewspace-144693/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/82392/viewspace-144693/