系统日志中报以下错误,从日志中可以确认为是内存J2900错误。
Jun 21 19:57:15 dg_inmsapp SUNW,UltraSPARC-III+: [ID 122499 kern.info] NOTICE:
[AFT0] Corrected system bus (CE) Event detected by CPU2 at TL=0, errID
0x005e32eb.cb02d774
Jun 21 19:57:15 dg_inmsapp AFSR 0x00000002.0000001f AFAR
0x00000040.21e02800
Jun 21 19:57:15 dg_inmsapp Fault_PC 0x100241f8 Esynd 0x001f Slot B: J2900
Jun 21 19:57:15 dg_inmsapp SUNW,UltraSPARC-III+: [ID 756928 kern.info] [AFT0]
errID 0x005e32eb.cb02d774 Corrected Memory Error on Slot B: J2900 is Persistent
Jun 21 19:57:15 dg_inmsapp SUNW,UltraSPARC-III+: [ID 446700 kern.info] [AFT0]
errID 0x005e32eb.cb02d774 Data Bit 16 was in error and corrected
Jun 21 19:57:15 dg_inmsapp SUNW,UltraSPARC-III+: [ID 636340 kern.info] [AFT2]
errID 0x005e32eb.cb02d774 E$tag PA=0x00000020.a0a02800 does not match
AFAR=0x00000040.21e02800
2、正常关闭系统并掉电。
#sync
#sync
#shutdown –y –g 0 –i 5
3、从机架上拆下机器,并打开盖板(盖板上有锁,需要先用钥匙打开),在机器的左侧面插有Slot A和Slot B两个CPU/Memory Module,先拆下Slot B模板两端的2个镙钉,然后按下图所示,拔出Slot B的CPU/Memory Modules。
4、戴上防静电手腕,按以下指示J2900位置更换更换内存。
5、更换完内存后,把CPU/Memory Modul插回Slot B,装上盖板。
6、对系统开始上电,并检查系统,确认更换内存后没有问题。
[@more@]来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/9479798/viewspace-1050067/,如需转载,请注明出处,否则将追究法律责任。