LEIZ_TEST更换硬盘操作步骤
对服务器进行硬盘的更换之前,要先做好os级的备份,操作步骤如下:
备注:请在hp工程师到位前对os进行备份,备份命令为
make_tape_recovery -Av |
1. 查看日志
LEIZ_TEST#[/]cd /var/opt/resmon/log LEIZ_TEST#[/var/opt/resmon/log]ls api.log client.log event.log registrar.log rst.log LEIZ_TEST#[/var/opt/resmon/log]vi event.log "event.log" 6399 行, 219948 个字节
>------------ Event Monitoring Service Event Notification ------------<
Notification Time: Sat Sep 27 12:48:04 2008
LEIZ_TEST sent Event Monitor notification information:
/storage/events/disks/default/1_0_1_1_0_1_1.6.0 is >= 1. Its current value is INFORMATION(1).
Event data from monitor:
Event Time..........: Sat Sep 27 12:48:04 2008 Severity............: INFORMATION Monitor.............: disk_em Event #.............: 100401 System..............: LEIZ_TEST
Summary: Disk at hardware path 1/0/1/1/0/1/1.6.0 : Successful completion of "event.log" 6399 行, 219948 个字节
v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v
Component Data: Physical Device Path...: 1/0/1/1/0/1/1.6.0 Device Class...........: Disk Inquiry Vendor ID......: HP 73.4G Inquiry Product ID.....: ST373454LC Firmware Version.......: HPC2 Serial Number..........: 3KP17RDX00007607ZL0J
Product/Device Identification Information:
Logger ID.........: sdisk Product Identifier: SCSI Disk Product Qualifier.: HP73.4GST373454LC SCSI Target ID....: 0x06 SCSI LUN..........: 0x00
I/O Log Event Data:
:q
|
2. ioscan
LEIZ_TEST#[/var/opt/resmon/log]ioscan -kfnCdisk Class I H/W Path Driver S/W State H/W Type Description ========================================================================== disk 0 1/0/0/3/0.6.0 sdisk CLAIMED DEVICE HP 73.4GST373454LC /dev/dsk/c0t6d0 /dev/rdsk/c0t6d0 disk 1 1/0/0/3/1.2.0 sdisk CLAIMED DEVICE _NEC DVD+RW NDD /dev/dsk/c1t2d0 /dev/rdsk/c1t2d0 disk 2 1/0/1/1/0/1/1.6.0 sdisk CLAIMED DEVICE HP 73.4GST373C /dev/dsk/c3t6d0 /dev/rdsk/c3t6d0 disk 3 1/0/6/1/1.0.0 sdisk CLAIMED DEVICE COMPAQ BD07288277 /dev/dsk/c5t0d0 /dev/rdsk/c5t0d0 disk 4 1/0/6/1/1.1.0 sdisk CLAIMED DEVICE COMPAQ BD07288277 /dev/dsk/c5t1d0 /dev/rdsk/c5t1d0
LEIZ_TEST#[/var/opt/resmon/log]ioscan -fnCtape Class I H/W Path Driver S/W State H/W Type Description ========================================================================== tape 1 1/0/1/1/0/1/0.1.0 stape CLAIMED DEVICE HP C5683A LEIZ_TEST#[/var/opt/resmon/log]ioscan -fnCtape Class I H/W Path Driver S/W State H/W Type Description ========================================================================== tape 1 1/0/1/1/0/1/0.1.0 stape CLAIMED DEVICE HP C5683A
LEIZ_TEST#[/var/opt/resmon/log]uname -a HP-UX LEIZ_TEST B.11.11 U 9000/800 192372456 不限用户数的许可证
|
3. 备份OS命令--备份到小磁带
192.168.203.66 2009-10-21日备份
LEIZ_TEST#[/var/opt/resmon/log]make_tape_recovery -Av * Creating local directories for configuration files and archive.
======= 10/21/09 14:22:08 EAT Started make_tape_recovery. (Wed Oct 21 14:22:08 EAT 2009) @(#) Ignite-UX Revision B.5.2.124 @(#) net_recovery (opt) $Revision: 10.624 $
======= 10/21/09 17:04:33 EAT make_tape_recovery completed successfully!
|
4. 取消2块盘之间的mirror
5. 更换新硬盘
6. 重新做mirror
7. 更换硬盘完成(并填写现场服务记录单)
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/9252210/viewspace-617153/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/9252210/viewspace-617153/