Applies to:
Oracle Workflow Cartridge - Version: 11.5.9 to 12.0.6 - Release: 11.5 to 12Information in this document applies to any platform.
Checked for relevance on 07-JAN-2011
Symptoms
When attempting to activate a business event subscription, the following error occurs:Warning
Cause
Value of Owner Tag field used in the Subscription creation steps (Step 2) is not a valid Application (product) Short Name that exists in FND_APPLICATION table.
from wf_event_subscriptions wes,
wf_events we
where wes.event_filter_guid = we.guid
and we.name like '&event_name';
select b.application_short_name
from FND_PRODUCT_INSTALLATIONS a,
FND_APPLICATION b
where b.application_id = a.application_id;
Solution
To bypass the issue follow below steps:
1. License the application into FND_PRODUCT_INSTALLATIONS table.
To license it, manually update the WF_EVENTS and WF_EVENT_SUBSCRIPTIONS tables to set the licensed_flag to 'Y'.
2. Change the Owner Tag to correspond to a valid Application_Short_Name from FND_APPLICATION table.
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/10359218/viewspace-716699/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/10359218/viewspace-716699/