In this Document
Symptoms
Cause
Solution
References
Applies to:
Enterprise Manager Grid Control - Version: 10.2.0.1This problem can occur on any platform.
Symptoms
Attempting to install Grid Control 10.2.0.1.0. All required libraries and kernel parameters have been set. The Oracle Universal Installer (OUI) runs the pre-checks and there are no failures. Everything runs fine during the install until the OMS Configuration Assistant (CA) runs. Then it fails with the following error:
INFO: Command = oracle.sysman.emcp.oms.OmsPlugIn -configureOms
Operation Stopping OPMN Processes is in progress.
Operation EM Deploying is in progress.
Operation Unlocking Passwords and Out of Box setup is in progress.
Command = oracle.sysman.emcp.oms.OmsPlugIn has failed
INFO: Configuration assistant "OMS Configuration" failed
SEVERE: OUI-25031:Some of the configuration assistants failed. It is strongly recommended that you retry the configuration assistants at this time. Not successfully running any "Recommended" assistants means your system will not be correctly configured.
Sometimes after using the work around and pressing retry, you will get this next error:
INFO: Starting to execute configuration assistants
INFO: Command = oracle.sysman.emcp.oms.OmsPlugIn -configureOms
Command = oracle.sysman.emcp.oms.OmsPlugIn has failed
Exception : java.lang.Exception: Error processing emkey command config emkey -repos -force from repository =
INFO: Configuration assistant "OMS Configuration" failed
Cause
OUI-25031 is a generic error message. One possible cause for this error could be bug.4755224 OMS CONFIGURATION FAILED DURING INSTALL OF 10.2. GRID.
Solution
The work around for the first error is1. Edit the listener.ora file add the parameter below:
SUBSCRIBE_FOR_NODE_DOWN_EVENT_=OFF
where would be replaced with the actual listener name configured in the
listener.ora file.
For example, if the listener name is LISTENER (default), the parameter would be:
SUBSCRIBE_FOR_NODE_DOWN_EVENT_LISTENER=OFF
2. Save the listener.ora file
3. Stop and restart the listener process
4. Retry the Configuration Assistant in the OUI (Click the retry button)
The workaround for the second error listed above is to edit the listener.ora file again and this time remove the following lines:
(ADDRESS_LIST =
(ADDRESS = (PROTOCOL = IPC)(KEY = EXTPROC))
)
Then save the file again, bounce the listener, and hit retry again. This time is should complete.
References
BUG:4755224 - OMS CONFIGURATION FAILED DURING INSTALL OF 10.2. GRID来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/17252115/viewspace-761039/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/17252115/viewspace-761039/