Make sure the terminal size if large enough for qemu. If not, "Floating point exception" error occurs.
$ qemu-system-arm xxxxxxxx \ -monitor telnet::5555,server,nowait
During the boot process inside the qemu-kvm utility, the screen was resized to the height of 1. A mouse click at this point caused a division by zero (the SIGFPE signal was sent) when calculating the absolute position of the pointer from the pixel. As a consequence, qemu-kvm terminated with the "Floating point exception" error. With this update, mouse click coordinates are forced to return values from the middle of the screen, so that qemu-kvm no longer terminates in the described scenario.
If "Floating point exception" occurs , can add "-nographic" start qemu, then restart with graphic again.
$ telnet localhost 5555 Trying ::1... Connection failed: Connection refused Trying 127.0.0.1... Connected to localhost. Escape character is '^]'. QEMU 0.10.50 monitor - type 'help' for more information (qemu)
(qemu) "ctrl+]" to return to telnet, (qemu)"quit" to exit qemu applicatoin.
(qemu) "system_reset" to reset machine, (qemu) "system_powerdown" to turn off the machine.