Summary
The following message is displayed in the developer trace files:
PfAddStatDura: overflow (217975<4294878038,307233), take max uint for <interval>
<interval> is the name of an SAP measurement interval. Examples:
STAT_READSEQ, STAT_COMMIT, STAT_DELETE and so on.
Statistics, ST03, time measurement
Cause and prerequisites
This error message is displayed as the result of summing up the individual measurement intervals inside a dialog step.
For the internal representation of this sum, a 32-bit number is used (value range 0 to 2^32=4294967296).
Because this measurement is performed in microseconds, this corresponds to a maximum duration of about 1 hour (4294 seconds).
If this value is exceeded, the above-mentioned warning message is output.
The message is not critical and may be ignored because a termination does not happen. However, you should generally check whether there is a reason for the long duration or whether it indicates a problem.