黄廷忠(网名:认真就输)
云和恩墨技术专家
个人博客:http://www.htz.pw/
本篇整理内容是黄廷忠在“云和恩墨大讲堂”微信分享中的讲解案例,SQL优化及SQL审核,是从源头解决性能问题的根本手段,无论是开发人员还是DBA,都应当持续深入的学习SQL开发技能,从而为解决性能问题打下根基。
本篇为系列案例之一:标量子查询优化
以下案例来自于某省电信系统EDW性能优化实践,数据库版本为11.2.0.3,运行在ORACLE Exadata一体机上,是个典型的OLAP环境,表上无索引,表无统计信息。
SQL性能问题诊断
SQL的基本逻辑如下:SELECt OFFER_SERV_SUM AS N37364,
LOCAL_CODE LOCAL_CODE,
AREA_ID AREA_ID,
DVLP_AREA_ID MG_AREA_ID,
DVLP_ORG_ID ORG_ID,
CASE
WHEN OFFER_SPEC_ID IN (SELECT LOCAL_ITEM_CODE
FROM PU_meta_DIM.CODE_ITEM
WHERe PROV_TYPE_ID = 49
AND PROV_ITEM_ID = 64) THEN
1 ELSE 0
END || CASE
WHEN TO_CHAr(OFFER_SPEC_ID) IN
(SELECt LOCAL_ITEM_CODE
FROM PU_meta_DIM.CODE_ITEM A
WHERe PROV_TYPE_ID = 49
AND PROV_ITEM_ID IN (85, 86, 68, 69, 70, 71)) THEN
1 ELSE 0
END || CASE
WHEN TO_CHAr(OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID
FROM PU_meta_DIM.D_DRAGON_PLAN
WHERe BT_CODE = 1
AND (UPPER(NAME) LIKE'%4S%'ORNAMELIKE'%??%')) THEN
1 ELSE 0
END || CASE
WHEN TO_CHAr(OFFER_SPEC_ID) IN
(SELECt LOCAL_ITEM_CODE
FROM PU_meta_DIM.CODE_ITEM
WHERe PROV_TYPE_ID = 49
AND PROV_ITEM_ID = 64) THEN
1 ELSE 0
END || CASE
WHEN TO_CHAr(OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID
FROM PU_meta_DIM.TY_SUIT_CFG) THEN
1 ELSE 0
END || CASE
WHEN TO_CHAr(OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID
FROM PU_meta_DIM.D_DRAGON_PLAN
WHERe BT_CODE = 2
AND (UPPER(NAME) LIKE'%4S%'ORNAMELIKE'%??%')) THEN
1 ELSE 0
END | C_ALL
FROM PU_base_IND.DM_SP_SUB_OFFER_SERV_D_201407
PARTITION(P20140727) A
WHERe LOCAL_CODE = '028'
这个SQL一共格式化出来有600多行,由于篇幅的限制,这里把其它一些无用的列的信息去掉。下面来查询一下SQL的执行计划:
从上面的关键字部分STORAGE FULL FIRST ROWS这部分,我们也可以看到是一个Exadata一体机的环境。
SQL的执行计划很简单,一共只有10行。FROM后对一个分区表的一个子分区执行全分区扫描。
下面来看看这个SQL每次执行消耗的物理读与逻辑读。
这里需要关注几点:1, 每次执行消耗的物理读(diskpre exec)
2, 每次执行平均消耗的逻辑读(getpre exec)
3, 每次执行平均返回的行数(rowspre exec)
这个脚本的输出我们还需要计算一下1, 每次执行SQL,返回的每行平均消耗的逻辑读338280770/4302704=78.62,大概逻辑读78才能换回一行。
2, 每次执行SQL,返回的每行平均消耗的物理读22610/4302704=0.005
从上面几点,大概知道这个SQL存在性能问题。
基础信息分析
PU_base_IND.DM_SP_SUB_OFFER_SERV_D_201407是个分区表,下面查询一下表分区的信息:
这里可以看到表是一个RANGE-LIST的分区表。下面查询SQL关联的表的大小:
由于是分区表,所有这里需要去查询访问的分区的大小:
这里看到访问的分区只有84M,加上code_item,ty_suit_cfg,d_dragon_plan表一共才4288 84=4372M,等于 =559616 个BLOCK。
下面我们考虑一种极端的条件下,SQL访问的几张表都走全表扫描,并且走HASH连接。那么此时物理读加逻辑读应该接近 559,616 (这里不考虑TEMP等消耗,不考虑事务一致性等原因,只考虑表的大小),但是整个SQL消耗的物理都为22610,逻辑读是:338,280,770。远远大于SQL访问的表占用的物理大小。所以初步判断在执行计划中存在某个对象被轮询。
下面查询访问的分区的行数,这里由于是OLAP系统,无统计信息,只能手动运行SQL来查询,如果有统计信息,可以大概根据统计信息来计算,虽然不是很准确,但是我觉得足够我们判断SQL性能了,何况CBO都是基于统计信息的。
这里看到028返回了400W行的数据。
问题定位与SQL改写
通过上面的信息,可以知道SQL变慢的原因:
由于PU_base_IND.DM_SP_SUB_OFFER_SERV_D_201407 PARTITION(P20140727) 返回一行,就需要去执行所有的标量子查询,虽然在一体机环境这里有first rows,但是所有的标量子查询被轮询的次数达到了4,302,704次,并且子查询的表走的全表扫描,所以出现了逻辑读很高。
逻辑读比物理读性能好,并且逻辑读消耗的时间很短,但是过高的逻辑读会带来CPU使用率的增加,RAC环境会导致过多的GC等待,还有可能会影响后来的一些TX,INDEX ITL等等待事件的出现,前不久就曾经遇到一个逻辑读导致GC等待,又引起了TX,INDEX ITL,BBW等待事件,没有多久,业务连接池就满了,最后整个业务受影响。
为了减少标量子查询被轮询的次数,这里可以把标量子查询改为外连接。
为了减少SQL长度,下面是去掉SELECt中一些不需要的部分,我们手动测试一下SQL改为外连接与原SQL执行SQL的差异:SELECT OFFER_SERV_SUM AS N37364,
LOCAL_CODE LOCAL_CODE,
AREA_ID AREA_ID,
DVLP_AREA_ID MG_AREA_ID,
DVLP_ORG_ID ORG_ID,
CASE WHEN a.OFFER_SPEC_ID = b.LOCAL_ITEM_CODE THEN 1 ELSE 0 END
|| CASE
WHEN TO_CHAr (a.OFFER_SPEC_ID) = e.LOCAL_ITEM_CODE THEN 1
ELSE 0
END
|| CASE
WHEN TO_CHAr (a.OFFER_SPEC_ID)= c.offer_spec_id
AND c.bt_code = 1
THEN
1
ELSE
0
END
|| CASE WHEN a.OFFER_SPEC_ID = b.LOCAL_ITEM_CODE THEN 1 ELSE 0 END
|| CASE
WHEN TO_CHAr (a.OFFER_SPEC_ID) = d.OFFER_SPEC_ID THEN 1
ELSE 0
END
|| CASE
WHEN TO_CHAr (a.OFFER_SPEC_ID)= c.offer_spec_id
AND c.bt_code = 2
THEN
1
ELSE
0
END
C_ALL
FROM PU_base_IND.DM_SP_SUB_OFFER_SERV_D_201407 PARTITION (P20140727) A,
(SELECt DISTINCT LOCAL_ITEM_CODE
FROM PU_meta_DIM.CODE_ITEM
WHERe PROV_TYPE_ID = 49 AND PROV_ITEM_ID = 64) b,
(SELECt DISTINCT OFFER_SPEC_ID, bt_code
FROM PU_meta_DIM.D_DRAGON_PLAN
WHERe BT_CODE IN (1, 2)
AND (UPPER (NAME) LIKE '%4S%' ORNAME LIKE '%??%')) c,
(SELECt DISTINCT OFFER_SPEC_ID FROM PU_meta_DIM.TY_SUIT_CFG) d,
(SELECt DISTINCT LOCAL_ITEM_CODE
FROM PU_meta_DIM.CODE_ITEM A
WHERe PROV_TYPE_ID = 49 AND PROV_ITEM_ID IN (85, 86, 68, 69, 70, 71)) e
WHERe LOCAL_CODE = '028'
AND a.OFFER_SPEC_ID = b.LOCAL_ITEM_CODE( )
AND TO_CHAr (a.OFFER_SPEC_ID) = c.OFFER_SPEC_ID( )
AND TO_CHAr (a.OFFER_SPEC_ID) = d.OFFER_SPEC_ID( )
AND TO_CHAr (a.OFFER_SPEC_ID) = e.LOCAL_ITEM_CODE( )
执行计划及统计信息:
这里可以看到所有的表都是通过HASH 来做UNIQUE
这里看到逻辑读是303475,行返回是4,302,704,不知道大家是否还记得在之前我们获取SQL的统计信息的时候,看到SQL每次执行平均换回的行数是4,302,704。
两个值是一样的,说明我们在此条SQL改写后是等价的。
这里用到了”此条”,因为如果在连接列有一些空值的情况下得到的结果可以不一样,大家可以测试一下。
性能优化效果对比
下面看看原SQL去掉SELECT不需要的部分执行的信息SELECT OFFER_SERV_SUM AS N37364,
LOCAL_CODE LOCAL_CODE,
AREA_ID AREA_ID,
DVLP_AREA_ID MG_AREA_ID,
DVLP_ORG_ID ORG_ID,
CASE
WHEN OFFER_SPEC_ID IN
(SELECT LOCAL_ITEM_CODE
FROMPU_meta_DIM.CODE_ITEM
WHERe PROV_TYPE_ID = 49AND PROV_ITEM_ID = 64)
THEN
1
ELSE
0
END
|| CASE
WHEN TO_CHAr (OFFER_SPEC_ID) IN
(SELECt LOCAL_ITEM_CODE
FROMPU_meta_DIM.CODE_ITEM A
WHERe PROV_TYPE_ID = 49
AND PROV_ITEM_IDIN (85, 86, 68, 69, 70, 71))
THEN
1
ELSE
0
END
|| CASE
WHEN TO_CHAr (OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID
FROMPU_meta_DIM.D_DRAGON_PLAN
WHERe BT_CODE = 1
AND ( UPPER (NAME) LIKE '%4S%'
OR NAME LIKE'%??%'))
THEN
1
ELSE
0
END
|| CASE
WHEN TO_CHAr (OFFER_SPEC_ID) IN
(SELECt LOCAL_ITEM_CODE
FROMPU_meta_DIM.CODE_ITEM
WHERe PROV_TYPE_ID = 49AND PROV_ITEM_ID = 64)
THEN
1
ELSE
0
END
|| CASE
WHEN TO_CHAr (OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID FROMPU_meta_DIM.TY_SUIT_CFG)
THEN
1
ELSE
0
END
|| CASE
WHEN TO_CHAr (OFFER_SPEC_ID) IN
(SELECt OFFER_SPEC_ID
FROM PU_meta_DIM.D_DRAGON_PLAN
WHERe BT_CODE = 2
AND ( UPPER (NAME) LIKE '%4S%'
OR NAME LIKE'%??%'))
THEN
1
ELSE
0
END
C_ALL
FROM PU_base_IND.DM_SP_SUB_OFFER_SERV_D_201407 PARTITION (P20140727) A
WHERe LOCAL_CODE = '028'
这条语句,运行了30分钟,都没有任何行返回:
可以看到执行了27分钟,才处理1908315,接近1/2的结果集行数。如果要处理完,估计需要60分钟以上。
总结
下面来总结一下此案例:1. 在标量子查询中,当主查询返回一行数据时,所有的标量子查询就要执行一次,如果在连接列有索引时,标量子查询在主表返回的行很少的情况下,对性能影响不大,常常出现在OLTP环境,并且连接列一般都有索引;如果在OLAP环境中,看到标量子查询千万要小心,通常,主表返回的行很多,并且子查询中的表通常在连接列上面无索引,导致性能很低下,本案例就是这种情况;
2. 平均每次执行时消耗的逻辑读、物理读,返回的行平均消耗的逻辑读、物理读,平均返回的行数等信息可以用于初步判断SQL是否存在性能问题;
遇到这种标量子查询,就得修改SQL,也就意味着业务需要修改代码,像电信运营商这种环境可能要好一点,有专门的开发团队,但是估计提交修改申请、开发修改、业务测试上线,差不多也要1到2个月的时间,如果在一些小的环境,估计开发商都找不到了,就跟谈不上改业务了。
12c新特性改进
对于类似以上的情况,在Oracle Database 12C中,优化器已经可以自动实现等价改写,但是需要注意的在12.1.0.2版本中有BUG,可能导致结果集不准确。
在12C中,标量子查询自动改写的功能由隐含参数 _optimizer_unnest_scalar_sq 控制,默认是TRUE,意味着开启,如果遇到BUG或者性能问题,可以更改为FALSE。
近期文章
新年贺礼:云和恩墨大讲堂期刊第二期
删繁就简-云和恩墨的一道面试题解析
用SQL解一道数学题:Gauss和Poincare
新年贺礼:云和恩墨大讲堂期刊发行
2015 Oracle 十大热门文章精选
Oracle 12c ASM 防火防盗新特性揭秘
DBA入门之路:学习与进阶之经验谈
DBA入门之路:关于日常工作的建议
业务架构
电子渠道(网络销售)分析系统、数据治理
IT基础架构
分布式存储解决方案 | zData一体机 | 容灾环境建设
数据架构
Oracle DB2 MySQL NoSQL
专项服务:架构/安全/容灾/优化/整合/升级/迁移
运维服务:运维服务 代维服务
人才培养:个人认证 企业内训
软件产品:SQL审核、监控、数据恢复
应用架构
应用软件和中间件:数据建模 | SQL审核和优化 | 中间件服务
本文分享自微信公众号 -