cacti添加被监控机全过程

在被监控端上的操作:

 1.在被监控机器上root目录下建立文件 test.sh

 chmod 777 test.sh

 cat test

 #!/bin/bash

 echo $RANDOM

 2.在snmpd.conf里添加如下内容

 extend .1.3.6.1.4.1.2021.2 test /root/test.sh

server端上操作

 1.取oid

[root@bogon]# snmpwalk -c public -v2c 172.16.21.154 .1.3.6.1.4.1.2021.2

UCD-SNMP-MIB::ucdavis.1.1.0 = INTEGER: 1

UCD-SNMP-MIB::ucdavis.1.2.1.2.4.116.101.115.116 = STRING: "/root/test.sh"

UCD-SNMP-MIB::ucdavis.1.2.1.3.4.116.101.115.116 = ""

UCD-SNMP-MIB::ucdavis.1.2.1.4.4.116.101.115.116 = ""

UCD-SNMP-MIB::ucdavis.1.2.1.5.4.116.101.115.116 = INTEGER: 5

UCD-SNMP-MIB::ucdavis.1.2.1.6.4.116.101.115.116 = INTEGER: 1

UCD-SNMP-MIB::ucdavis.1.2.1.7.4.116.101.115.116 = INTEGER: 1

UCD-SNMP-MIB::ucdavis.1.2.1.20.4.116.101.115.116 = INTEGER: 4

UCD-SNMP-MIB::ucdavis.1.2.1.21.4.116.101.115.116 = INTEGER: 1

UCD-SNMP-MIB::ucdavis.1.3.1.1.4.116.101.115.116 = STRING: "13135"

UCD-SNMP-MIB::ucdavis.1.3.1.2.4.116.101.115.116 = STRING: "13135"

UCD-SNMP-MIB::ucdavis.1.3.1.3.4.116.101.115.116 = INTEGER: 1

UCD-SNMP-MIB::ucdavis.1.3.1.4.4.116.101.115.116 = INTEGER: 0

UCD-SNMP-MIB::ucdavis.1.4.1.2.4.116.101.115.116.1 = STRING: "13135"

 [root@bogon ]# snmpwalk -c public -v2c 172.16.21.154.1.3.6.1.4.1.2021.1.4.1.2.4.116.101.115.116.1

 UCD-SNMP-MIB::ucdavis.1.4.1.2.4.116.101.115.116.1 = STRING: "13446"

 最终为取得oid为

 .1.3.6.1.4.1.2021.2.4.1.2.4.116.101.115.116.1

 2.在server端添加被监控主机的步骤

console————〉devices—————〉add

 添加数据模版

create之后在oid里面填入上面获取的oid

添加数据源:

 添加图像模版

 

 添加图像管理

添加图像管理树

 