linux 硬盘热备,MegaCli64使用热备盘替换故障硬盘实操

我们这台故障机器是12盘位的戴尔EMC,10盘组raid10+1盘热备,安装MegaCli64看下面这个链接:

Proxmox(Debian)安装MegaCli64管理硬件Raid阵列卡root@JS-2002:~/megacli/Linux# MegaCli64 -LDInfo -Lall -aALL

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)

Name :

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

Size : 9.093 TB

Sector Size : 512

Mirror Data : 9.093 TB

State : Degraded

Strip Size : 64 KB

Number Of Drives per span:2

Span Depth : 5

Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

Is VD Cached: No

Exit Code: 0x00

root@JS-2002:~/megacli/Linux# MegaCli64 -pdinfo -physdrv[:3] -a0

Enclosure Device ID: N/A

Slot Number: 3

Drive's position: DiskGroup: 0, Span: 1, Arm: 1

Enclosure position: N/A

Device Id: 3

WWN: 5000C500260EACC4

Sequence Number: 2

Media Error Count: 0

Other Error Count: 5

Predictive Failure Count: 3

Last Predictive Failure Event Seq Number: 30255

PD Type: SAS

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.818 TB [0xe8d00000 Sectors]

Sector Size: 0

Firmware state: Online, Spun Up

Device Firmware Level: 0008

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x5000c500260eacc5

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST32000444SS 00089WM3PSCZ

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 6.0Gb/s

Media Type: Hard Disk Device

Drive: Not Certified

Drive Temperature :29C (84.20 F)

PI Eligibility: No

Drive is formatted for PI information: No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 6.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : Yes

Exit Code: 0x00

然后设置这个磁盘下线,同时标记missing:

root@JS-2002:~/megacli/Linux# MegaCli64 -PDOffline -PhysDrv [:3] -a0

Adapter: 0: EnclId-N/A SlotId-3 state changed to OffLine.

Exit Code: 0x00

root@JS-2002:~/megacli/Linux# MegaCli64 -pdmarkmissing -physdrv[:3] -aAll

EnclId-N/A SlotId-3 is marked Missing.

Exit Code: 0x00

标记这个硬盘准备移除:

root@JS-2002:~/megacli/Linux# MegaCli64 -pdprprmv -physdrv[:3] -a0

Prepare for removal Success

Exit Code: 0x00

这时候再看阵列的状态, 是Degraded:

root@JS-2002:~/megacli/Linux# MegaCli64 -LDInfo -Lall -aALL

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)

Name :

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

Size : 9.093 TB

Sector Size : 512

Mirror Data : 9.093 TB

State : Degraded

Strip Size : 64 KB

Number Of Drives per span:2

Span Depth : 5

Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

Is VD Cached: No

Exit Code: 0x00

然后将”热备”盘顶上,之前没有添加热备,只是插上了而已,这里最重要的是确定Array和row的参数是啥,找了好久….

实际上Raid10是将多组raid1的磁盘组成raid0阵列,所以在我们这里10盘的Raid10实际分成了5组Raid0。也就是这里面Array后面的参数。而row就是这每个raid1小组里面的0或者1,这样以来就好理解了,只要磁盘的Span号即可:

Enclosure Device ID: N/A

Slot Number: 3

Drive's position: DiskGroup: 0, Span: 1, Arm: 1

Enclosure position: N/A

Device Id: 3

是Array1,row1,于是:

root@JS-2002:~/megacli/Linux# MegaCli64 -PdReplaceMissing -PhysDrv[:10] -Array1 -row1 -a0

Adapter: 0: Failed to replace Missing PD at Array 1, Row 1.

FW error description:

The specified device is in a state that doesn't support the requested command.

Exit Code: 0x32

替换失败了,是因为这个盘作为一个普通non-raid盘存在,所以我们直接把这块盘拔掉,然后插到3号盘的位置,神奇的开始rebuild了:

Coerced Size: 1.818 TB [0xe8d00000 Sectors]

Sector Size: 0

Firmware state: Rebuild

Device Firmware Level: HPD7

注意:本段内容须“登录”后方可查看!

This article is under CC BY-NC-SA 4.0 license.

Please quote the original link:https://www.liujason.com/article/391.html

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?