我目前正在尝试在商业路由器(Ursalink的UR71)和modbus RTU(施耐德电气的ZBRN2)之间建立modbus通信。在
UR71路由器运行在Linux OpenWRT LEDE-17.01上
Python是v2.7.13
Python使用的是modbus tk 0.5.7和pyserial 3.4
我的应用程序需要modbus读取(FC03)和modbus多次写入(FC16)
问题是我成功地用我的计算机(windows 10)作为modbus主机运行,但当我切换到作为modbus主机的UR71时,FC16不再工作并发送:(, ModbusInvalidResponseError('Response length is invalid 0',), )
我做了一个小应用程序给你看:
^{pr2}$
Modbus初始化如下:rtu = ur71_modbus.UR71RTU(ur71_init.port_id, ur71_init.baudrate)
rtu.set_timeout(2.0)
rtu.set_verbose(True)
对于包含串行配置的UR71RTU:ser = serial.Serial(port=self.dev, baudrate=baudrate, bytesize=serial.EIGHTBITS, parity=serial.PARITY_EVEN, stopbits=serial.STOPBITS_ONE, xonxoff=0)
这导致:2.7.13 (default, Aug 21 2018, 20:45:19)
run.py [2018-11-30 14:00:58 PM] [INFO] Modbus initialization
ur71_modbus.py [2018-11-30 14:00:58 PM] [DEBUG] Linux
modbus_rtu.py [2018-11-30 14:00:58 PM] [INFO] RtuMaster /dev/ttyS1 is opened
run.py [2018-11-30 14:00:58 PM] [DEBUG] Reading modbus FC03...
modbus.py [2018-11-30 14:00:58 PM] [DEBUG] -> 1-3-23-212-0-60-0-87
modbus.py [2018-11-30 14:00:58 PM] [DEBUG]
run.py [2018-11-30 14:00:58 PM] [DEBUG] (0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0)
run.py [2018-11-30 14:00:59 PM] [DEBUG] Reading modbus FC06...
modbus.py [2018-11-30 14:00:59 PM] [DEBUG] -> 1-6-7-218-15-1-109-117
modbus.py [2018-11-30 14:00:59 PM] [DEBUG]
run.py [2018-11-30 14:00:59 PM] [DEBUG] (2010, 3841)
modbus.py [2018-11-30 14:00:59 PM] [DEBUG] -> 1-6-7-218-16-1-101-69
modbus.py [2018-11-30 14:00:59 PM] [DEBUG]
run.py [2018-11-30 14:00:59 PM] [DEBUG] (2010, 4097)
run.py [2018-11-30 14:01:00 PM] [DEBUG] Reading modbus FC16...
modbus.py [2018-11-30 14:01:00 PM] [DEBUG] -> 1-16-7-218-0-1-2-15-1-7-154
modbus.py [2018-11-30 14:01:02 PM] [DEBUG]
run.py [2018-11-30 14:01:02 PM] [ERROR] (, ModbusInvalidResponseError('Response length is invalid 0',), )
run.py [2018-11-30 14:01:02 PM] [DEBUG]
Windows中的相同代码会导致:2.7.15 (v2.7.15:ca079a3ea3, Apr 30 2018, 16:30:26) [MSC v.1500 64 bit (AMD64)]
INFO:modbus_tk:RtuMaster COM4 is opened
DEBUG:ur71:Serial link checked
DEBUG:ur71:Reading modbus FC03...
DEBUG:modbus_tk:-> 1-3-23-212-0-60-0-87
DEBUG:modbus_tk:
DEBUG:ur71:(0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0)
DEBUG:ur71:Reading modbus FC06...
DEBUG:modbus_tk:-> 1-6-7-218-15-1-109-117
DEBUG:modbus_tk:
DEBUG:ur71:(2010, 3841)
DEBUG:modbus_tk:-> 1-6-7-218-16-1-101-69
DEBUG:modbus_tk:
DEBUG:ur71:(2010, 4097)
DEBUG:ur71:Reading modbus FC16...
DEBUG:modbus_tk:-> 1-16-7-218-0-1-2-15-1-7-154
DEBUG:modbus_tk:
DEBUG:ur71:(2010, 1)
DEBUG:modbus_tk:-> 1-16-7-218-0-1-2-16-1-15-170
DEBUG:modbus_tk:
DEBUG:ur71:(2010, 1)
DEBUG:ur71:
我不知道是什么引起了这个问题。在我调查了超时(最多10秒)、字节间超时等等,但如果它适用于FC06,为什么FC16会有所不同呢?在
我用minimamodbus lib测试,问题是一样的,所以我不认为错误来自modbus tk lib
我在这里已经没有办法了,如果有人已经遇到这种问题,我会很感激你的帮助。
也许Linux和Windows上的串行端口有一些不同之处,我现在不知道(但是为什么FC06可以工作?)?在
谨致问候