早上登陆服务器,发现大量警告Log,如下:
事件类型: 警告
事件来源: PlugPlayManager
事件种类: 无
事件 ID: 257
日期: 2009-3-2
事件: 10:34:39
用户: N/A
计算机: NICEGAIN-SW741B
描述:
将目标设备更改通知发送到 "C:\WINNT\Explorer.EXE" 的窗口时超时
事件来源: PlugPlayManager
事件种类: 无
事件 ID: 257
日期: 2009-3-2
事件: 10:34:39
用户: N/A
计算机: NICEGAIN-SW741B
描述:
将目标设备更改通知发送到 "C:\WINNT\Explorer.EXE" 的窗口时超时
有关更多信息,请参阅在
[url]http://go.microsoft.com/fwlink/events.asp[/url] 的帮助和支持中心。
去软微官网找资料,发现该日志相关信息如下:
Your event log may contain events that are similar the following:
Event Type: Warning Event Source: PlugPlayManager Event Category: None Event ID: 257 Date: 1/12/2004 Time: 10:48:04 PM User: N/A Computer: EXCH11 De.ion: Timed out sending notification of target device change to window of "VDS Notification Thread Hidden Window {417F6FAB-6A56-49C6-B9A9-6A795A0C73C1}"
原因:
These events may be logged when both of the following conditions are true:
- A high volume of disk I/O operations are performed.
- A time-out occurs during the interaction between Logical Disk Manager (LDM) and Plug and Play (PNP).
看来服务器磁盘的SATA盘的I/O,将可能会成为服务器性能的瓶颈。