IBM的双机双柜,两光纤交换机分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。需改为不同号。下面是博科的交换机命令转。

Brocade SAN交换机常用命令

使用电脑连接管理网口,默认IP地址为:192.168.0.1,掩码:255.255.255.0

默认用户名:admin,默认密码password

1. switchStatusShow

查看交换机的总体健康状态

switch:admin> switchstatusshow

Switch Health Report

Switch Name: SWFCR

IP address: 10.33.54.176

SwitchState: MARGINAL

Duration: 863:23

Power supplies monitor MARGINAL

Temperatures monitor HEALTHY

Fans monitor HEALTHY

WWN servers monitor HEALTHY

Standby CP monitor HEALTHY

Blades monitor HEALTHY

Flash monitor HEALTHY

Marginal ports monitor HEALTHY

Faulty ports monitor HEALTHY

Missing SFPs monitor HEALTHY

All ports are healthy

switch:admin>

2. switchShow

查看交换机基本配置信息

Enter the switchShow command, which displays the following information for a switch:

- switchname - The switch name.

- switchtype - The switch model and firmware version numbers.

- switchstate - The switch state: Online, Offline, Testing, or Faulty.

- switchrole - Displays the switch role: Principal, Subordinate, or Disabled.

- switchdomain - Displays the switch Domain ID.

- switchid - The embedded port D_ID of the switch.

- switchwwn - The switch World Wide Name.

- switchbeacon - The switch beaconing state: either ON or OFF.

The switchShow command also displays the following information for ports on the specified

switch:

- Module type - The SFP type if an SFP is present.

- Port speed - The speed of the Port (1G, 2G, 4G, N1, N2, N4, or AN). The speed can be

fixed, negotiated, or auto-negotiated.

- Port state - The port status.

- Comment - About the port. This section may be blank or display the WWN for an F_Port or

an E_Port, the trunking state, or upstream or downstream status

3. portShow

查看端口状态

switch:admin> switch:user> portshow 0

portName:

portHealth: OFFLINE

Authentication: None

portDisableReason: None

portCFlags: 0x1

portFlags: 0x4001 PRESENT U_PORT LED

portType: 4.1

portState: 2 Offline

portPhys: 2 No_Module

portScn: 0

port generation number: 0

portId: 010000

portIfId: 43020020

portWwn: 20:00:00:60:69:00:02:53

portWwn of device(s) connected:

Distance: normal

portSpeed: N2Gbps

LE domain: 0

Interrupts: 0 Link_failure: 0 Frjt: 0

Unknown: 0 Loss_of_sync: 0 Fbsy: 0

Lli: 0 Loss_of_sig: 0

Proc_rqrd: 0 Protocol_err: 0

Timed_out: 0 Invalid_word: 0

Rx_flushed: 0 Invalid_crc: 0

Tx_unavail: 0 Delim_err: 0

Free_buffer: 0 Address_err: 0

Port part of other ADs: Yes

4. fanShow

查看交换机散热风扇的状态

Enter the fanShow command:

switch:admin> fanshow

Fan 1 is OK speed is 7010 RPM

Fan 2 is OK speed is 7180 RPM

Fan 3 is OK speed is 7068 RPM

Fan 4 is OK speed is 7116 RPM

Fan 5 is OK speed is 7155 RPM

Fan 6 is OK speed is 7001 RPM

switch:admin>

5. psShow

查看交换机的电源状态

注:如果安装FR4-18i、FC4-16IP、FC10-6、FC8-48板,需要满配4个电源

Enter the psShow command:

switch:admin> psshow

Power Supply #1 is OK

0335,FF2Z0007161,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007161

Power Supply #2 is faulty

0335,FF2Z0007176,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007176

switch:admin>

6. tempShow

查看交换机的环境温度

Enter the tempShow command:

switch:admin> tempshow

Index Status Centigrade Fahrenheit

----------------------------------------------------

1 OK 21 70

2 OK 22 72

3 OK 29 84

4 OK 24 75

5 OK 25 77

switch:admin>

7. errDump、errShow、errClear

查看交换机的内部消息日志

To display the system message log, with no page breaks

Enter the errDump command.

To display the system message log one at a time

Enter the errShow command.

To clear the system message log

Enter the errClear command.

8. supportShow、supportSave、pdShow

收集交换机的诊断数据

supportShow

显示诊断信息和状态信息

supportSave

将数据打包、上传至指定的FTP服务器

The command prompts for an FTP server, packages the following files, and sends them to the specified server:

? The output of the supportShow command

? The contents of any trace dump files on the switch

? System message logs (for Brocade directors, supportSave saves the system message logs

from both of the CP blades)

pdShow

显示panic dump文件的内容,帮助诊断系统panic的原因

9. nsShow、nsAllShow、fabricShow

检查连接到交换机的设备

nsShow

显示连接到交换机的所有设备

nsAllShow

显示连接到Fabric的所有设备

fabricShow

显示Fabric中的所有交换机

10. licenseShow、wwn

检查license文件和交换机的WWN号

11. version

检查Fabric OS的版本,将显示如下信息:

- Kernel: displays the version of switch kernel operating system.

- Fabric OS: displays the version of switch Fabric OS.

- Made on: displays the build date of firmware running in switch.

- Flash: displays the install date of firmware stored in nonvolatile mem