与大多数思科路由器相似,6500和7600系列路由器密码恢复都可以在rommon模式下进行。
    特别注意:Sup720、Sup32和RSP720等都有两个处理器,即SP(Switch Processor)和RP(Router Processor)。
    开机或重启,过程中会看到如下信息,表明进入RP处理:
      00:00:28: %OIR-SP-6-CONSOLE: Changing console ownership to route processor
      此时,按住 Ctrl+Break,而不是SP开始时(如果是,那你进入的是SP的rommon,而不是RP的rommon)。在ROMMON模式下,输入0x2142,然后reset,重启即可。剩余操作同其它路由器相同。
      备注:
     Configuration Registers

      The global configuration command - config-register is used to modify the behaviour of the router. Weather or not it boots from saved configuration. Weather or not it boots from the flash or the boot-proms.

      In summary these Boot Registers are quite handy:

  • The value range is from 0x0 to 0xFFFF.
  • 0x2102 is the factory-default configuration register value.
  • 0x2142 boots from flash without using NVRAM contents good for password recovery.
  • 0x2101 boots from boot prom image not flash, good for upgrading image on flash.
  • 0x2141 boots from boot prom and ignores NVRAM contents.
  • 0x141, which disables the Break key, ignores the NVRAM configuration, and
    boots the default system image from ROM.