解决前状态

1、接口配置

interface TenGigabitEthernet3/1

 description To C4507-387-standby-10G

 switchport mode trunk

 channel-group 40 mode on

end


2、接口状态

SW-SJHL-2C-386-Core#show interfaces tenGigabitEthernet 3/1

TenGigabitEthernet3/1 is down, line protocol is down (inactive) 

  Hardware is Ten Gigabit Ethernet Port, address is 1cdf.0f51.8140 (bia 1cdf.0f51.8140)

  Description: To C4507-387-standby-10G

  MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec, 

     reliability 255/255, txload 1/255, rxload 1/255

  Encapsulation ARPA, loopback not set

  Keepalive set (10 sec)

  Full-duplex, 10Gb/s, link type is auto, media type is No X2

  input flow-control is off, output flow-control is off

  ARP type: ARPA, ARP Timeout 04:00:00

  Last input never, output never, output hang never

  Last clearing of "show interface" counters never

  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0

  Queueing strategy: fifo

  Output queue: 0/40 (size/max)

  5 minute input rate 0 bits/sec, 0 packets/sec

  5 minute output rate 0 bits/sec, 0 packets/sec

     0 packets input, 0 bytes, 0 no buffer

     Received 0 broadcasts (0 multicasts)

     0 runts, 0 giants, 0 throttles

     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored

     0 input packets with dribble condition detected

     0 packets output, 0 bytes, 0 underruns

     0 output errors, 0 collisions, 3 interface resets

     0 babbles, 0 late collision, 0 deferred

     0 lost carrier, 0 no carrier

     0 output buffer failures, 0 output buffers swapped out

SW-SJHL-2C-386-Core#



3、报错log日志

Jan 21 02:16:15: %C4K_GLMMAN-3-TWINGIGCONVERTERIDENTFAILED: Port Te3/1: Failed to identify TwinGig Converter


解决办法

1、转换接口的类型模式

hw-module module 3 port-group 1 select tengigabitethernet

hw-module module 3 port-group 2 select tengigabitethernet

2、再次查看接口类型

SW-SJHL-2C-386-Core#show interfaces tenGigabitEthernet 3/1

TenGigabitEthernet3/1 is down, line protocol is down (notconnect) 

  Hardware is Ten Gigabit Ethernet Port, address is 1cdf.0f51.8140 (bia 1cdf.0f51.8140)

  Description: To C4507-387-standby-10G

  MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec, 

     reliability 255/255, txload 1/255, rxload 1/255

  Encapsulation ARPA, loopback not set

  Keepalive set (10 sec)

  Full-duplex, 10Gb/s, link type is auto, media type is No X2

  input flow-control is off, output flow-control is off

  ARP type: ARPA, ARP Timeout 04:00:00

  Last input never, output never, output hang never

  Last clearing of "show interface" counters never

  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0

  Queueing strategy: fifo

  Output queue: 0/40 (size/max)

  5 minute input rate 0 bits/sec, 0 packets/sec

  5 minute output rate 0 bits/sec, 0 packets/sec

     0 packets input, 0 bytes, 0 no buffer

     Received 0 broadcasts (0 multicasts)

     0 runts, 0 giants, 0 throttles

     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored

     0 input packets with dribble condition detected

     0 packets output, 0 bytes, 0 underruns

     0 output errors, 0 collisions, 3 interface resets

     0 babbles, 0 late collision, 0 deferred

     0 lost carrier, 0 no carrier

     0 output buffer failures, 0 output buffers swapped out

SW-SJHL-2C-386-Core#