The C2-1006 and C2-1010 messages are output reporting internal link errors without hardware fault. This is associated with Good EOF CRC errors.
SERDES tuning was enhanced to address CRC with good EOF errors on the HP DC SAN Backbone Director with the 48-port 8Gb FC Blade and
the 64-port 8Gb FC Blade, and on the HP DC04 SAN Director Switch with the 48-port 8Gb FC Blade and the 16-port 8Gb FC Blade.Fixed in Fabric OS 7.0.1b.
目前的系统fw是Fabric OS: v7.0.0c
HP建议:
1.升级FW到Fabric OS 7.0.1b
2.如果还报出类似的错误,那么更换S1 blade
转载于:https://blog.51cto.com/121688/1337415