Cisco 路由器 xmodem重新快速安装IOS<?xml:namespace prefix = o ns = "urn:schemas-microsoft-com:office:office" />

 

先打开超级终端,进入rommon 模式(Ctrl+Break组合键),键入confreg, 如下:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
rommon 1 > confreg
回车

Configuration Summary
enabled are:
load rom after netboot fails
console baud: 9600
boot: p_w_picpath specified by the boot system commands
or default to: cisco2-C2600

do you wish to change the configuration? y/n [n]: y ( 选择 yes)
enable "diagnostic mode"? y/n [n]: n (
选择 no)
enable "use net in IP bcast address"? y/n [n]: n (
选择 no)
disable "load rom after netboot fails"? y/n [n]: n (
选择 no)
enable "use all zero broadcast"? y/n [n]: n (
选择 no)
enable "break/abort has effect"? y/n [n]: n (
选择 no)
enable "ignore system config info"? y/n [n]: n (
选择 no)
change console baud rate? y/n [n]: y (
选择 yes)
enter rate: 0 = 9600, 1 = 4800, 2 = 1200, 3 = 2400
4 = 19200, 5 = 38400, 6 = 57600, 7 = 115200 [0]: 7 (
选择 7,用最大的115200速率的xmodem传输)
change the boot characteristics? y/n [n]: n (
选择 no)


Configuration Summary
enabled are:
load rom after netboot fails
console baud: 115200
boot: p_w_picpath specified by the boot system commands
or default to: cisco2-C2600

do you wish to change the configuration? y/n [n]: n ( 选择 no)


You must reset or power cycle for new config to take effect

rommon 2 > reset 回车

注意:在此时键入 reset键之前,开始定义串口速度(我的电脑---端口属性----串口速度调为115200),然后再修改超级终端里设置速率为115200,记住,一定这么做!否则出现乱码!然后关闭这个超级终端,重新建立一个超级终端连接,(期间系统重新启动)启动后,出现

rommon 1> 提示符
然后,输入
rommon 1> xmodem -r


Do not start the sending program yet...

Invoke this application only for disaster recovery.
Do you wish to continue? y/n [n]: y (
选择 yes)
Ready to receive file ...

此时,在超级终端的菜单上的传送”---“发送文件”----选择IOS镜像文件所在地以及选择使用“xmodem”协议,点击发送即可

然后等待10-20分钟左右就把3<?xml:namespace prefix = st1 ns = "urn:schemas-microsoft-com:office:smarttags" />-6MIOS灌进去了!

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
(修改回计算机串口与超级终端、路由器confreg下的xmodem9600的传输速率)

videre注:实际用的时候,我发现这个命令总是改不成功,后来发现在line con 0下面有了一个speed 115200,所以即使改register成功,启动以后router又执行speed 115200,还是不行,所以如果有这个问题,记得把这个语句no掉)


Router>en
进入新IOS的特权模式

Router#reload 重启系统

Proceed with reload? [confirm] 回车

00:01:04: %SYS-5-RELOAD: Reload requested
System Bootstrap, Version 11.3(2)XA4, RELEASE SOFTWARE (fc1)
Copyright (c) 1999 by cisco Systems, Inc.
TAC:Home:SW:IOS:Specials for info
PC = 0xfff0a530, Vector = 0x500, SP = 0x680127b0
C2600 platform with 24576 Kbytes of main memory

PC = 0xfff0a530, Vector = 0x500, SP = 0x80004684

monitor: command "boot" aborted due to user interrupt

rommon 1 > confreg ( 输入“confreg”命令)


Configuration Summary
enabled are:
load rom after netboot fails
console baud: 115200
boot: p_w_picpath specified by the boot system commands
or default to: cisco2-C2600

do you wish to change the configuration? y/n [n]: y ( 选择 yes)
enable "diagnostic mode"? y/n [n]: n (
选择 no)
enable "use net in IP bcast address"? y/n [n]: n (
选择 no)
disable "load rom after netboot fails"? y/n [n]: n (
选择 no)
enable "use all zero broadcast"? y/n [n]: n (
选择 no)
enable "break/abort has effect"? y/n [n]: n (
选择 no)
enable "ignore system config info"? y/n [n]: n (
选择 no)
change console baud rate? y/n [n]: y (
选择 yes)
enter rate: 0 = 9600, 1 = 4800, 2 = 1200, 3 = 2400
4 = 19200, 5 = 38400, 6 = 57600, 7 = 115200 [7]: 0 (
选择 0,改回用标准速率速率9600xmodem传输)
change the boot characteristics? y/n [n]: n (
选择 no)

Configuration Summary
enabled are:
load rom after netboot fails
console baud: 9600
boot: p_w_picpath specified by the boot system commands
or default to: cisco2-C2600

do you wish to change the configuration? y/n [n]: n

You must reset or power cycle for new config to take effect
rommon 2 >

此时手工改回计算机串口与超级终端2者传输速率为9600

然后敲入
rommon 2 >reset
(
最好关电源)