计算机X线摄片检查,ASTM E2033-2017

5.1x00a0;This practice establishes the basic parameters for the application and control of the CR examination method. This practice is written so it can be specified on the engineering drawing, specification, or contract.

5.2x00a0;Weld Examinationx2014;Additional information on weld examination may be found in Practice E1032, ISO 17636-2, or both.

5.3x00a0;Casting Examinationx2014;Additional information on casting examination may be found in Practice E1030.

5.4x00a0;Electronic Componentsx2014;Radiographic examination of electronic components shall comply with Practice E1161.

5.5x00a0;Part-Specific Examination Techniquex2014;A detailed written procedure in the form of a part-specific examination technique (7.5) shall be documented for each part, or group of parts, and shall be approved by the Cognizant Radiographic Level 3.

5.6x00a0;Personnel Qualificationx2014;Personnel performing examinations to this practice shall be qualified in accordance with ISO 9712, NAS 410, EN 4179, ANSI/ASNT CP 189, or SNT-TC-1A and certified by the employer or certifying agency as applicable. Other equivalent qualification documents may be used when specified on the contract or purchase order. The applicable revision shall be the latest unless otherwise specified in the contractual agreement between parties.

5.7x00a0;System Qualificationx2014;All CR systems shall be qualified for their intended use. System qualification requirements are specified in subsection 7.1.

5.8x00a0;Process Controlx2014;All CR systems shall be monitored for long term stability (process control) as specified in subsection 7.1.4.

5.9x00a0;Preventative Maintenancex2014;All CR systems and X-ray machines require periodic maintenance to ensure proper functionality. Preventative maintenance requirements are specified in subsection 6.2.

5.10x00a0;Environmental Conditionsx2014;CR systems should be operated within environmental conditions that are in compliance with manufacturerx2019;s stated acceptable environmental conditions, e.g., temperature and humidity. When CR systems are operated outside the specified manufacturerx2019;s environmental ranges, the system shall be qualified (7.1) for such conditions.

1.1x00a0;This practice establishes the minimum requirements for computed radiographic (CR) examina......