使用Lsiutil管理Dell SAS 6i/R
Dell的好多型號(如R410,R610)服務器默認的RAID控制器都是SAS 6i/R ,對於這款控制器MegaCli是不能使用的。在命令行模式下想管理SAS 6i/R,需要使用Lsiutil這個工具。
Lsiutil有兩種使用方法: 菜單驅動的交互使用 和 命令行
不帶任何參數執行lsiutil,就會進入lsiutil的交互模式。在這個模式下,所有的操作都是通過文本菜單來進行的,舉例如下:
[root@Dell1950 ~]# lsiutil
LSI Logic MPT Configuration Utility, Version 1.56, March 19, 2008
1 MPT Port found
Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC
1. /proc/mpt/ioc0 LSI Logic SAS1068E B3 105 00192f00 0
Select a device: [1-1 or 0 to quit] 1
1. Identify firmware, BIOS, and/or FCode
2. Download firmware (update the FLASH)
4. Download/erase BIOS and/or FCode (update the FLASH)
8. Scan for devices
10. Change IOC settings (interrupt coalescing)
13. Change SAS IO Unit settings
16. Display attached devices
20. Diagnostics
21. RAID actions
22. Reset bus
23. Reset target
42. Display operating system names for devices
45. Concatenate SAS firmware and NVDATA files
60. Show non-default settings
61. Restore default settings
69. Show board manufacturing information
97. Reset SAS link, HARD RESET
98. Reset SAS link
99. Reset port
e Enable expert mode in menus
p Enable paged mode
w Enable logging
Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21
1. Show volumes
2. Show physical disks
3. Get volume state
4. Wait for volume resync to complete
23. Replace physical disk
26. Disable drive firmware update mode
27. Enable drive firmware update mode
30. Create volume
31. Delete volume
32. Change volume settings
33. Change volume name
50. Create hot spare
99. Reset port
e Enable expert mode in menus
p Enable paged mode
w Enable logging
RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 1
1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring)
Volume Name:
Volume WWID: 0a09acf0a136af86
Volume State: optimal, enabled
Volume Settings: write caching disabled, auto configure, priority resync
Volume draws from Hot Spare Pools: 0
Volume Size 139392 MB, 2 Members
Primary is PhysDisk 1 (Bus 0 Target 9)
Secondary is PhysDisk 0 (Bus 0 Target 1)
RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 0
Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0
Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC
1. /proc/mpt/ioc0 LSI Logic SAS1068E B3 105 00192f00 0
Select a device: [1-1 or 0 to quit] 0
命令行模式舉例如下:
lsiutil –p1 –a 21,1,0,0,0 和上邊菜單操作一樣,只不過不用手動去選擇菜單項了
lsiutil -p 1 -i –s 顯示端口1的設置和連接的設備
lsiutil –s 顯示所有端口上連接的設備
lsiutil -p 2 -l 1 強制HBA卡端口2連接速度為1Gb