linux 巡检手册,服务器设备系统巡检标准手册.doc

服务器设备系统巡检标准手册

PC服务器设备巡检

2.1 Linux系统巡检

2.1.1 Linux系统设备列表

IP服务器名称系统类型机器型号10.122.1.106邮件系统服务器ARedhat LinuxIBM System x3850 x510.122.1.107邮件系统服务器BRedhat LinuxIBM System x3850 x510.122.1.14新门户应用服务器1Redhat LinuxDELL R91010.122.1.15新门户应用服务器2Redhat LinuxDELL R91010.122.1.16新门户应用服务器3Redhat LinuxDELL R91010.122.1.17新门户应用服务器4Redhat LinuxDELL R91010.122.1.247新门户内容管理Cms服务器1Redhat LinuxIBM System x3850 x510.122.1.248新门户内容管理Cms服务器2Redhat LinuxIBM System x3850 x510.122.1.249新门户内容管理Cms服务器3Redhat LinuxIBM System x3850 x510.122.10.142营销应用服务器1Redhat LinuxHP Proliant DL580 G510.122.10.143营销应用服务器2Redhat LinuxHP Proliant DL580 G510.122.10.144营销应用服务器3Redhat LinuxHP Proliant DL580 G510.122.10.145营销应用服务器4Redhat LinuxHP Proliant DL580 G510.122.10.146营销应用服务器5Redhat LinuxHP Proliant DL580 G510.122.10.147营销应用服务器6Redhat LinuxHP Proliant DL580 G510.122.10.148营销应用服务器7Redhat LinuxHP Proliant DL580 G510.122.10.149营销应用服务器8Redhat LinuxHP Proliant DL580 G510.122.10.156营销文档服务器1号机Redhat LinuxHP Proliant DL580 G510.122.10.158营销文档服务器2号机Redhat LinuxHP Proliant DL380 G510.122.10.159营销银电联网服务器1Redhat LinuxHP Proliant DL580 G510.122.10.161营销银电联网服务器2Redhat LinuxHP Proliant DL380 G510.122.10.162营销电能量采集服务器1Redhat LinuxHP Proliant DL580 G5 10.122.6.64PMS应用服务器3Redhat LinuxIBM X-Serise 385010.122.6.65PMS应用服务器2Redhat LinuxIBM X-Serise 385010.122.6.66PMS应用服务器1Redhat LinuxIBM X-Serise 385010.122.7.112新门户数据库1Redhat LinuxDELL R91010.122.7.113电子公章安全传输服务器Redhat LinuxDELL R910

2.1.2 Linux系统巡检标准

检查项 检查操作 参考标准 检查结果CPU 占用率#topCPU 使用率小于80%□ 正常 □ 异常 说明: ____________ 内存占用率#top内存使用率小于80%□ 正常 □ 异常 说明: ____________ 内存交换区使用率#top内存交换区使用率小于70%□ 正常 □ 异常 说明: ____________ 文件系统占用率#df -h没有文件系统超过 80%的现象□ 正常 □ 异常 说明: ____________

Linux服务器巡检指导 "设备 " " "硬件配置信息 " "机型号 " " "CPU " " "内存 " " "硬盘 " " "系统信息 " "操作系统 " " "IP " " "主机名 " " (一)服务器硬件检查 "检查项 "检查操作 "参考标准 "巡检情况 " " " " " " "机柜或者机器上的 "观察机柜以及机器上的 "是否在防尘上堵塞导 " " "防尘网 "防尘网上的灰尘 "致气流不畅。 " " " " " " " "系统风扇运转检查 "观察并用手感觉进风和 "主机和磁盘柜的所有 " " " "出风是否正常 "风扇运转正常。 " " " " " " " "系统运装噪音检查 "仔细听系统运转声音 "噪音是否过大,有无 " " " " "异常声音 " " " " " " " "系统电源指示灯检 "观察液晶面板、电源指 "液晶面板、电源指示 " " "查 "示灯、硬盘报警灯等显 "灯、硬盘报警灯等显 " " " "示 "示情况正常 " " " " " " " " "服务器硬盘工作状 "硬盘指示灯指示是否正 "绿色闪烁 " " " "态 "常,一般绿色为正常 " " " " "检查网线是否连接 " " " " " "正常 "检查网线与交换机之间 "交换机连接主机的所 " " " " "的连线是否正常,以及 "有端口指示灯为长亮 " " " " "双机心跳网线连接是否 ",双机系统的公网与 " " " " "正常 "交换机之间的连接应 " " " " " "为交叉连接。 " " " " "服务器插上网线后,若 " " " " " "有数据传输,则网卡指 " " " " " "示灯呈现规律性闪烁; " " " " "服务器网卡工作状 "若闪烁不正常或指示灯 "网卡指示灯正常闪烁 " " " "态 "指示颜色不正常,则说 " " " " " "明系统数据传输将不正 " " " " " "常 " " " " " " " " " " "服务器散热检测 "靠近服务器检查是否有 " " " " " "热风吹出 " " " " " " " " " " "服务器电源连接检 "电源连接线是否有松动 " " " " "查 "、接触不良等情况 " " " " " " " " " " "服务器外壳整体检 "服务器整体是否有移动 " " " " "查 "或损害痕迹 " " " " "服务器机房温度 "机房的温度是否异常变 "参考值温度:20 -26 " " " " "动,温度数值多少 " " " " " " " " " " "服务器机房湿度 "机房的湿度是否异常变 "参考值温度:45%-60%" " " " "动,湿度计数值多少 " " " " " " " " " " "服务器机房静电防 "防静电地板是否损坏, " " " " "护 "防静电设备是否正常 " " " " " " " " " " "服务器标签检查 "标签是否松动、脱落, " " " " " "字体是否模糊不清 " " " " (二)操作系统检查 "检查项 "检查操作 "参考标准 "巡检情况 " "操作系统版本检查 "执行命令uname -a " " " " " " " " " " "系统账户检查 "利用root身份、口令登"能够正常登陆到系统 " " " "陆 " " " " " " " " "系统运行状态 "#uptime "系统UP时间应该为上次" " " " "重启到目前的时间 " " " " (二)性能检查 "检查项 "检查操作 "参考标准 "巡检情况 " "检查各进程资源CPU占用率 " "CPU使用率小于80% " " " "#top -c " " " "检查各进程资源内存占用率 " "内存使用率小于80% " " " "#top –c " " " "检查各进程资源内存交换区使" "内存交换区使用率小" " "用率 "#top –c "于80% " " " " " " " " "#top –c 进程名 "察看系统最占资源的" " "进出占用资源检查 " "进程 " " " " "察看具体某个进程占" " " " "用资源的具体情况 " " Top命令 统计信息区 前五行是系统整体的统计信息。第一行是任务队列信息,同 uptime 命令的执行结果。其内容如下: "16:35:22 "当前时间 " " up 17 day 5:45"系统运行时间,格式为时:分 " "4 user "当前登录用户数 " "load average: "系统负载,即任务队列的平均长度。 三个数值分别 " "0.15, 0.15, "为 1分钟、5分钟、15分钟前到现在的平均值。 " "0.08 " " "Tasks: 366 "进程总数 " "total " " "1 running "正在运
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值