山东中道消防设备有限公司(九通长胜)生产的化工液体运输车辆超细干粉自动灭火装置、水基型自动灭火装置、全氟己酮自动灭火系统适用于各地区危化品车辆使用。通过对爆破器材运输车、油罐汽车、物流运输车、化工液体运输车、背罐车、扒渣机、液体运输车、气瓶运输车等汽车火灾特性分析,提出了一种能够实现多级预警和自动灭火的汽车防灭火方案,并通过汽车发动机舱模拟火灾试验,在证明了其工作可靠性的同时优化了系统的报警功能和灭火功能。本文为大家介绍超细干粉自动灭火系统技术应用特点 。

Shandong Zhongdao Fire Equipment Co., LTD. (Jiutong Changsheng) produces ultra-fine dry powder automatic fire extinguishing device, water-based automatic fire extinguishing device and perfluorohexanone automatic fire extinguishing system for chemical liquid transport vehicles, which are suitable for use by hazardous chemical vehicles in various regions. By blasting equipment truck, oil tank car, logistics carriers, chemical liquid truck, back, grilled slag machine, liquid tanker truck, truck cylinders, such as auto fire characteristic, put forward a kind of can realize auto fire-fighting scheme of multistage warning and automatic fire extinguishing, and through the car engine compartment fire simulation test, while work has proved its reliability optimization of the system's function and fire alarm function. This paper introduces the application characteristics of the super fine dry powder automatic fire extinguishing system.

268f920a99fd1e3c3927b78bd490c321.png

结构特点:Structural features:

机械式定温型超细干粉自动灭火装置由灭火剂储存罐体、K型感温探头探测装置、压力显示部件组成,可固定于墙壁上,具有不占地、无电气连接、安装简便的特点。 火灾时可自动喷放灭火剂的一类灭火装置。超细干粉自动灭火装置的阀门设计通径大,喷放时间短、灭火迅速。由于没有管网,施工安装简单,减少工程投资;同是灭火装置安装在防护区上空或四周墙壁上,可不占用防护区地面空间。

The mechanical constant temperature ultrafine dry powder automatic fire extinguishing device is composed of extinguishing agent storage tank, K-type temperature sensing probe detection device and pressure display unit, which can be fixed on the wall. It has the characteristics of no floor space, no electrical connection and easy installation. A type of fire extinguisher which can automatically spray extinguishing agent in case of fire. The valve of the super fine powder automatic fire extinguishing device has large design size, short spraying time and fast fire extinguishing. Because there is no pipe network, the construction and installation are simple, reducing the project investment; Both fire extinguishing devices shall be installed above the protected area or on the surrounding walls, and shall not occupy the ground space of the protected area.