linux断电后硬盘报错,vsphere虚拟机下的Linux在线移除硬盘后的报错处理(基于LVM)...

当一块被设置为pv格式的硬盘在VMware虚拟机中在线移除后,出现unknowndevice错误。通过使用vgreduce --removemissing命令移除丢失的物理卷,并在确认fstab信息无误后重启系统,成功解决了I/O错误。此过程未影响/mnt中的数据。
摘要由CSDN通过智能技术生成

1)故障描述( vmware虚拟机,在线移除一块被设置为pv格式的硬盘后,提示unknown device错误):

说明:/dev/sdb1 /dev/sdc1 /dev/sdd1是组成/dev/vg_test/lvm_test的PV,这里我们模拟/dev/sdd1硬盘被直接断电了

[root@docker mnt]# pvdisplay

/dev/sdd: read failed after 0 of 4096 at 0: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error

/dev/sdd: read failed after 0 of 4096 at 4096: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error

/dev/sdd1: read failed after 0 of 512 at 0: Input/output error

/dev/sdd1: read failed after 0 of 512 at 4096: Input/output error

/dev/sdd1: read failed after 0 of 2048 at 0: Input/output error

Couldn't find device with uuid 166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp.

--- Physical volume ---

PV Name               /dev/sdb1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes (but full)

PE Size               4.00 MiB

Total PE              5118

Free PE               0

Allocated PE          5118

PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X

--- Physical volume ---

PV Name               /dev/sdc1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes

PE Size               4.00 MiB

Total PE              5118

Free PE               5116

Allocated PE          2

PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp

--- Physical volume ---

PV Name               unknown device

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes

PE Size               4.00 MiB

Total PE              5118

Free PE               5118

Allocated PE          0

PV UUID               166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp

2)处理步骤:

[root@docker mnt]# vgreduce --removemissing vg_test

/dev/sdd: read failed after 0 of 4096 at 0: Input/output error

/dev/sdd1: read failed after 0 of 2048 at 0: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error

/dev/sdd: read failed after 0 of 4096 at 4096: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error

/dev/sdd1: read failed after 0 of 512 at 0: Input/output error

/dev/sdd1: read failed after 0 of 512 at 4096: Input/output error

Couldn't find device with uuid 166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp.

Wrote out consistent volume group vg_test

[root@docker mnt]# vgchange -a y

/dev/sdd: read failed after 0 of 4096 at 0: Input/output error

/dev/sdd1: read failed after 0 of 2048 at 0: Input/output error

1 logical volume(s) in volume group "vg_test" now active

[root@docker mnt]# df -h

Filesystem            Size  Used Avail Use% Mounted on

/dev/sda3             193G   14G  170G   8% /

tmpfs                 1.9G  228K  1.9G   1% /dev/shm

/dev/sda1             190M   80M  100M  45% /boot

/dev/mapper/vg_test-lvm_test

20G   28M   19G   1% /mnt

测试表明:整个过程都不会影响/mnt中的数据运行

[root@docker mnt]# pvdisplay

/dev/sdd: read failed after 0 of 4096 at 0: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error

/dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error

/dev/sdd: read failed after 0 of 4096 at 4096: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error

/dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error

/dev/sdd1: read failed after 0 of 512 at 0: Input/output error

/dev/sdd1: read failed after 0 of 512 at 4096: Input/output error

/dev/sdd1: read failed after 0 of 2048 at 0: Input/output error

--- Physical volume ---

PV Name               /dev/sdb1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes (but full)

PE Size               4.00 MiB

Total PE              5118

Free PE               0

Allocated PE          5118

PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X

--- Physical volume ---

PV Name               /dev/sdc1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes

PE Size               4.00 MiB

Total PE              5118

Free PE               5116

Allocated PE          2

PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp

发现仍旧有I/O的错误出现,找到合适停机窗口,重启了系统,故障得到解决(这里注意重启前检查fstab信息,看下mount -a是否有报错)。

[root@docker ~]# pvdisplay

--- Physical volume ---

PV Name               /dev/sdb1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes (but full)

PE Size               4.00 MiB

Total PE              5118

Free PE               0

Allocated PE          5118

PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X

--- Physical volume ---

PV Name               /dev/sdc1

VG Name               vg_test

PV Size               19.99 GiB / not usable 1.43 MiB

Allocatable           yes

PE Size               4.00 MiB

Total PE              5118

Free PE               5116

Allocated PE          2

PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp

这样,系统就已经没有报错信息了。