为什么linux会伤固态硬盘,解决Linux下SSD写入过高的问题

root@h3:~# smartctl -a /dev/nvme0n1

smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-106-generic] (local build)

Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===

Model Number: Samsung SSD 970 EVO Plus 500GB

Serial Number: S*************P

Firmware Version: 1B2QEXM7

PCI Vendor/Subsystem ID: 0x144d

IEEE OUI Identifier: 0x002538

Total NVM Capacity: 500,107,862,016 [500 GB]

Unallocated NVM Capacity: 0

Controller ID: 4

Number of Namespaces: 1

Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]

Namespace 1 Utilization: 134,237,945,856 [134 GB]

Namespace 1 Formatted LBA Size: 512

Local Time is: Mon Jun 15 09:30:17 2020 CST

Firmware Updates (0x16): 3 Slots, no Reset required

Optional Admin Commands (0x0017): Security Format Frmw_DL *Other*

Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat *Other*

Maximum Data Transfer Size: 512 Pages

Warning Comp. Temp. Threshold: 85 Celsius

Critical Comp. Temp. Threshold: 85 Celsius

Supported Power States

St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat

0 + 7.80W - - 0 0 0 0 0 0

1 + 6.00W - - 1 1 1 1 0 0

2 + 3.40W - - 2 2 2 2 0 0

3 - 0.0700W - - 3 3 3 3 210 1200

4 - 0.0100W - - 4 4 4 4 2000 8000

Supported LBA Sizes (NSID 0x1)

Id Fmt Data Metadt Rel_Perf

0 + 512 0 0

=== START OF SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0x1)

Critical Warning: 0x00

Temperature: 50 Celsius

Available Spare: 100%

Available Spare Threshold: 10%

Percentage Used: 5%

Data Units Read: 2,961,897 [1.51 TB]

Data Units Written: 138,624,034 [70.9 TB]

Host Read Commands: 32,871,818

Host Write Commands: 3,360,464,283

Controller Busy Time: 3,161

Power Cycles: 47

Power On Hours: 7,880

Unsafe Shutdowns: 33

Media and Data Integrity Errors: 0

Error Information Log Entries: 87

Warning Comp. Temperature Time: 0

Critical Comp. Temperature Time: 0

Temperature Sensor 1: 50 Celsius

Temperature Sensor 2: 46 Celsius

Error Information (NVMe Log 0x01, max 64 entries)

No Errors Logged

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值