Hi,
I received an error I never came across before:
Check results for process LOADING ZPAK_... in chain .. :
Message no. RSPC135
Process type LOADING is only released for use in BW standard client
Message no. RSPC125
The IP was active. The PC was not active, but could be manually activated.
The IP was not transported, just the PC, which failed to activate due to this error.
Importing with overwrite originals did not help.
Does anyone have any idea please?
Thanks
Martin
Former Member
November 12, 2015 at 17:12 PM
0 Likes
Correct Answer
Former Member replied
July 01, 2013 at 12:05 PM
One workaround:
Goto RSA1-->Administration tab--> Click on Process Chains-->Goto Settings on Top-->Maintain process types -->Select the LOADING process type, go to extreme right of the record. You will find BW only Column. Please un check this and save on top.
Regards,
Suman