Linux使用storcli工具查看服务器硬盘和raid组信息

/ex = Enclosure ID

/sx = Slot ID

1.5为了管理方便,建立软连接

ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli

ln -s /opt/MegaRAID/storcli/storcli64    /sbin/storcli

如果不想建立软连接,就在/opt/MegaRAID/storcli 目录下 执行./storcli64 指令

2、查看当前设备raid控制器相关信息

[root@localhost storcli]# ./storcli64 show all    可以看到只有一个控制器

Status Code = 0

Status = Success

Description = None

Number of Controllers = 1

Host Name = localhost.localdomain

Operating System  = Linux2.6.32-358.el6.x86_64

System Overview :

===============


Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs


0 Mini      8  14   3     0   3     0 Opt On  3  N      0      【
只看到一个控制器】


Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed

PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal

Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown

sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare

Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit

ASO :

===


Ctl


0


Cl=Cluster|MD=Max Disks|WC=Wide Cache|SS=Safe Store|FP=Fast Path|Re=Recovery

CR=CacheCade(Read)|RF=Reduced Feature Set|CO=Cache Offload

CW=CacheCade(Read/Write)|X=Not Available/Not Installed|U=Unlimited|T=Trial

3、查看控制器c0的相关信息

[root@localhost storcli]# ./storcli64  /c0 show

Controller = 0

Status = Success

Description = None

Product Name =
PERC H710P Mini【控制器型号】

Serial Number = 26300UP

SAS Address =  5d4ae520a6bcbc00

Mfg. Date = 06/04/12

System Time = 05/22/2019 16:22:28

Controller Time = 05/22/2019 08:22:28

FW Package Build = 21.0.2-0001

BIOS Version = 5.30.00_4.12.05.00_0x05110000

FW Version = 3.130.05-1587

Driver Name = megaraid_sas

Driver Version = 06.504.01.00-rh1

Controller Bus Type = N/A

PCI Slot = N/A

PCI Bus Number = 2

PCI Device Number = 0

PCI Function Number = 0

Drive Groups = 3

TOPOLOGY :

========


DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace


0 -   -   -        -   RAID1 Optl  N  278.875 GB dflt N  N   dflt N

0 0   -   -        -   RAID1 Optl  N  278.875 GB dflt N  N   dflt N

0 0   0   32:24    24  DRIVE Onln  N  278.875 GB dflt N  N   dflt -

0 0   1   32:25    25  DRIVE Onln  N  278.875 GB dflt N  N   dflt -

1 -   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N

1 0   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N

1 0   0   32:0     0   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

1 0   1   32:1     1   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

1 0   2   32:2     2   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

1 0   3   32:3     3   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

1 0   4   32:4     4   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

1 0   5   32:5     5   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 -   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N

2 0   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N

2 0   0   32:6     6   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 0   1   32:7     7   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 0   2   32:8     8   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 0   3   32:9     9   DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 0   4   32:10    10  DRIVE Onln  N   837.75 GB dflt N  N   dflt -

2 0   5   32:11    11  DRIVE Onln  N   837.75 GB dflt N  N   dflt -     
【可以看到服务器有几个RAID,每个RAID的级别和成员盘】


DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID

DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded

Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active

PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign

DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present

Virtual Drives = 3【服务器有三个RAID,两个RAID5一个RAID1】

VD LIST :

=======


DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name


0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB

1/1   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB

2/2   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB


Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

Physical Drives = 14【十四个物理磁盘】

PD LIST :

=======


EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp


32:0      0 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:1      1 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:2      2 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:3      3 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:4      4 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:5      5 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:6      6 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:7      7 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:8      8 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:9      9 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:10    10 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:11    11 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U

32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U


EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign

BBU_Info :

========


Model State   RetentionTime Temp Mode MfgDate    Next Learn


BBU   Optimal 0 hour(s)     30C  0    2011/07/18 None


4、获取enclosure信息

硬盘大多是附在enclosure上不是直接附在controller上。

显示所有的enclosure信息,但是系统中只有一个enclosure ,EID:32.

[root@localhost storcli]# ./storcli64 /c0/eall show

Controller = 0

Status = Success

Description = None

Properties :

==========


EID State Slots PD PS Fans TSs Alms SIM Port#       ProdID    VendorSpecific


32 OK       26 14  0    0   0    0   0 Unavailable BP12G+EXP


EID-Enclosure Device ID |PD-Physical drive count |PS-Power Supply count|

TSs-Temperature sensor count |Alms-Alarm count |SIM-SIM Count

获取单个enclosure  ,e32详细信息

[root@localhost storcli]# ./storcli64 /c0/e32 show all

Controller = 0

Status = Success

Description = None

Enclosure /c0/e32  :

==================

Information :

===========

Device ID = 32

Position = 1

Connector Name = Unavailable

Enclosure Type = SES

Status = OK

FRU Part Number = N/A

Enclosure Serial Number = N/A

ESM Serial Number = N/A

Enclosure Zoning Mode = N/A

Partner Device ID = 65535

Inquiry Data :

============

Vendor Identification = DP

Product Identification = BP12G+EXP

Product Revision Level = 1.07

Properties :

==========


EID State Slots PD PS Fans TSs Alms SIM Port#       ProdID    VendorSpecific


32 OK       26 14  0    0   0    0   0 Unavailable BP12G+EXP


EID-Enclosure Device ID |PD-Physical drive count |PS-Power Supply count|

TSs-Temperature sensor count |Alms-Alarm count |SIM-SIM Count

5、显示物理磁盘信息

语法:storcli64  /cx/eall/sall show  显示所有物理磁盘信息

[root@localhost storcli]# ./storcli64 /c0/e32/sall   show 【
显示e32上的所有物理硬盘

[root@localhost storcli]# ./storcli64 /c0/eall/sall show【
显示所有enclosure下的所有物理硬盘

Controller = 0

Status = Success

Description = Show Drive Information Succeeded.

Drive Information :

=================


EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp


32:0      0 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:1      1 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:2      2 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:3      3 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:4      4 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:5      5 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:6      6 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:7      7 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:8      8 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:9      9 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:10    10 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:11    11 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U

32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U

32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U


EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare【表示有热备盘,DHS专有热备,GHS全局热备】

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign

从上面信息,可以看出:

  • 只有一个控制器,id 为 0
  • EID,Enclosure Device ID :32
  • Slot Number,能看到 0,1,2,3,4,5,6,7,8,9,10,11,24,25
  • DG:disk group,0,1,2
  • size:容量,磁盘容量
  • intf:接口,SAS
  • Med:介质,ssd 或 hdd

6、查看raid组详细信息

查看系统里面有几个raid组:

[root@localhost storcli]# ./storcli64 /c0/vall  show 【查看c0控制下的所有RAID信息】

Controller = 0

Status = Success

Description = None

Virtual Drives :

==============


DG/
VD TYPE  State Access Consist Cache Cac sCC       Size Name


0/
0  RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB

1/
1  RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB

2/
2   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB     
【显示系统有三个raid组】


Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

查看V0  (虚拟磁盘0) raid的详细信息

[root@localhost storcli]# ./storcli64 /c0/v0 show all

Controller = 0

Status = Success

Description = None

/c0/v0 :

======


DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name


0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB     
【V0为RAID1】

自我介绍一下,小编13年上海交大毕业,曾经在小公司待过,也去过华为、OPPO等大厂,18年进入阿里一直到现在。

深知大多数软件测试工程师,想要提升技能,往往是自己摸索成长或者是报班学习,但对于培训机构动则几千的学费,着实压力不小。自己不成体系的自学效果低效又漫长,而且极易碰到天花板技术停滞不前!

因此收集整理了一份《2024年软件测试全套学习资料》,初衷也很简单,就是希望能够帮助到想自学提升又不知道该从何学起的朋友,同时减轻大家的负担。
img
img
img
img
img

既有适合小白学习的零基础资料,也有适合3年以上经验的小伙伴深入学习提升的进阶课程,基本涵盖了95%以上软件测试开发知识点,真正体系化!

由于文件比较大,这里只是将部分目录大纲截图出来,每个节点里面都包含大厂面经、学习笔记、源码讲义、实战项目、讲解视频,并且后续会持续更新

如果你觉得这些内容对你有帮助,可以添加V获取:vip1024b (备注软件测试)
img

一个人可以走的很快,但一群人才能走的更远。不论你是正从事IT行业的老鸟或是对IT行业感兴趣的新人,都欢迎扫码加入我们的的圈子(技术交流、学习资源、职场吐槽、大厂内推、面试辅导),让我们一起学习成长!

ess Consist Cache Cac sCC       Size Name


0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB     
【V0为RAID1】

自我介绍一下,小编13年上海交大毕业,曾经在小公司待过,也去过华为、OPPO等大厂,18年进入阿里一直到现在。

深知大多数软件测试工程师,想要提升技能,往往是自己摸索成长或者是报班学习,但对于培训机构动则几千的学费,着实压力不小。自己不成体系的自学效果低效又漫长,而且极易碰到天花板技术停滞不前!

因此收集整理了一份《2024年软件测试全套学习资料》,初衷也很简单,就是希望能够帮助到想自学提升又不知道该从何学起的朋友,同时减轻大家的负担。
[外链图片转存中…(img-rF4pIhEs-1712883174167)]
[外链图片转存中…(img-9f3b40qD-1712883174168)]
[外链图片转存中…(img-1zXLHTLx-1712883174168)]
[外链图片转存中…(img-h6xj77js-1712883174169)]
[外链图片转存中…(img-Ctsv2ZwZ-1712883174169)]

既有适合小白学习的零基础资料,也有适合3年以上经验的小伙伴深入学习提升的进阶课程,基本涵盖了95%以上软件测试开发知识点,真正体系化!

由于文件比较大,这里只是将部分目录大纲截图出来,每个节点里面都包含大厂面经、学习笔记、源码讲义、实战项目、讲解视频,并且后续会持续更新

如果你觉得这些内容对你有帮助,可以添加V获取:vip1024b (备注软件测试)
[外链图片转存中…(img-WmDI8myJ-1712883174170)]

一个人可以走的很快,但一群人才能走的更远。不论你是正从事IT行业的老鸟或是对IT行业感兴趣的新人,都欢迎扫码加入我们的的圈子(技术交流、学习资源、职场吐槽、大厂内推、面试辅导),让我们一起学习成长!

  • 10
    点赞
  • 18
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值