MP日志如下:
[mp0014c29cd28f] MP:CM> ps
PS
For System Processor Status see the SS command.
System Power state : Off
System Power usage : 42 Watts used in Auxiliary Mode
Ambient temperature: 26 C
Temperature status : Normal
Power supplies State
-----------------------------------------------------------
Power Supply 0 Normal
Power Supply 1 Normal
Fans State
-----------------------------------------------------------
System Fan 1 Failure
System Fan 2 Failure
System Fan 3 Failure
System Fan 4 Normal
System Fan 5 Normal
System Fan 6 Normal
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >
Log Entry 70: 09 Dec 2015 10:41:28
Alert Level 7: Fatal
Keyword: SHUTDOWN_OR_RESET_ON_SENSOR
System shut down or reset caused by sensor reading
Logged by: Baseboard Management Controller;
Sensor: System Event - System Fan 1
Data2: OEM Code2: 0xF0
0x2056680558020880 F000A870F0120300
Log Entry 68: 09 Dec 2015 10:39:28
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 3
Data1: transition to Critical from less severe
0x20566804E0020850 FFFF0207F20A0300
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >
Log Entry 67: 09 Dec 2015 10:39:28
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 2
Data1: transition to Critical from less severe
0x20566804E0020840 FFFF0207F10A0300
Log Entry 66: 09 Dec 2015 10:39:28
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 1
Data1: transition to Critical from less severe
0x20566804E0020830 FFFF0207F00A0300
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >
Log Entry 51: 06 Dec 2015 07:46:06
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 3
Data1: transition to Critical from less severe
0x205663E7BE020700 FFFF0207F20A0300
Log Entry 50: 06 Dec 2015 07:46:06
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 2
Data1: transition to Critical from less severe
0x205663E7BE0206F0 FFFF0207F10A0300
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >
Log Entry 49: 06 Dec 2015 07:46:05
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 1
Data1: transition to Critical from less severe
0x205663E7BD0206E0 FFFF0207F00A0300
Log Entry 35: 06 Dec 2015 07:06:51
Alert Level 7: Fatal
Keyword: SHUTDOWN_OR_RESET_ON_SENSOR
System shut down or reset caused by sensor reading
Logged by: Baseboard Management Controller;
Sensor: System Event - System Fan 1
Data2: OEM Code2: 0xF0
0x205663DE8B0205F0 F000A870F0120300
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >
Log Entry 33: 06 Dec 2015 07:04:51
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 3
Data1: transition to Critical from less severe
0x205663DE130205C0 FFFF0207F20A0300
Log Entry 32: 06 Dec 2015 07:04:51
Alert Level 5: Critical
Keyword: COOLING_UNIT_FAILURE
Cooling unit failure
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - System Fan 2
Data1: transition to Critical from less severe
0x205663DE130205B0 FFFF0207F10A0300
更换三个风扇后故障未消除,又换中板 仍然报错,最后换完IO板后故障消除。。