12V start battery strategy- eg. LFP battery
Balancing Protection
Balancing: 20-30mA
Trigger of balancing: Umax ∈ \in ∈ [3.5, 4.0] & Temp ∈ \in ∈ [0 or-10, 50 or 60] & Voltage no abnormalities.
Trigger of balancing elimination: Umax < 3.3 or 3.4 & Temp ∈ \in ∈ [0 or-10, 50 or 60] & Voltage no abnormalities.
Trigger of single parallel balancing: Uthecell - Umin≥100mV & Uthecell > 3.3V.
Trigger of single parallel balancing elimination: Uthecell < 3.2V or δ \delta