Failing item name | Physical location code | Identify LED |
---|---|---|
System unit | Un | |
Fans | ||
Fan 1 | Un-A1 | Yes |
Fan 2 | Un-A2 | Yes |
Fan 3 | Un-A3 | Yes |
Fan 4 | Un-A4 | Yes |
Power supplies | ||
Power supply 1 | Un-E1 | Yes |
Power supply 2 | Un-E2 | Yes |
Backplanes | ||
Input/output backplane with embedded:
| Un-P1 | Yes |
Battery | Un-P1-E1 | |
DASD and media backplane | Un-P2 | Yes |
System backplane ports | ||
System serial port 1 (rear view - left connector) | Un-P1-T1 | |
System serial port 2 (rear view - right connector) | Un-P1-T2 | |
Embedded USB front port | Un-D1-T1 | |
Embedded USB rear port 1 | Un-P1-T3 | |
Embedded USB rear port 2 | Un-P1-T4 | |
SPCN port 1 (rear view - left connector) | Un-P1-T5 | |
SPCN port 2 (rear view - right connector) | Un-P1-T6 | |
HMC 1 (rear view - left connector) | Un-P1-T7 | |
HMC 2 (rear view - right connector) | Un-P1-T8 | |
Dual 10 GB Ethernet port 1 (top RJ45 connector) | Un-P1-C6-T1 | |
Dual 10 GB Ethernet port 2 (bottom RJ45 connector) | Un-P1-C6-T2 | |
Quad 1 GB Ethernet port 1 (top RJ45 connector) | Un-P1-C6-T1 | |
Quad 1 GB Ethernet port 2 (middle top RJ45 connector) | Un-P1-C6-T2 | |
Quad 1 GB Ethernet port 3 (middle bottom RJ45 connector) | Un-P1-C6-T3 | |
Quad 1 GB Ethernet port 4 (bottom RJ45 connector) | Un-P1-C6-T4 | |
External SAS port | Un-P2-T1 | |
Processor and processor regulator | ||
POWER7™ Processor card 1 | Un-P1-C13 | Yes |
POWER7 Processor card 2 | Un-P1-C14 | Yes |
POWER7 Processor card 3 | Un-P1-C15 | Yes |
POWER7 Processor card 4 | Un-P1-C16 | Yes |
Memory VRM (Vcc, Vdimm, Vtt) | Un-P1-C13-C10 | Yes |
Memory VRM (Vcc, Vdimm, Vtt) | Un-P1-C14-C10 | Yes |
Memory VRM (Vcc, Vdimm, Vtt) | Un-P1-C15-C10 | Yes |
Memory VRM (Vcc, Vdimm, Vtt) | Un-P1-C16-C10 | Yes |
VPD card | Un-P1-C9 | Yes |
Adapters | ||
PCI-E x8 adapter in slot 1 | Un-P1-C1 | Yes |
PCI-E x8 adapter in slot 2 | Un-P1-C2 | Yes |
PCI-E x8 adapter in slot 3 | Un-P1-C3 | Yes |
PCI-X 2.0 adapter in slot 4 | Un-P1-C4 | Yes |
PCI-X 2.0 adapter in slot 5 | Un-P1-C5 | Yes |
HEA Ethernet card | Un-P1-C6 | Yes |
GX 12X channel adapters controller slot 1 (rear view - second slot from center) | Un-P1-C8 | Yes |
GX Dual-Port 12X Channel Attach adapter controller slot 2 (rear view - first slot from center) | Un-P1-C7 | Yes |
GX 12X channel adapterscontroller slot 1 port 1 (top connector) | Un-P1-C8-T1 | No |
GX 12X channel adapters controller slot 1 port 2 (bottom connector) | Un-P1-C8-T2 | No |
GX Dual-Port 12X Channel Attach adapter controller slot 2 port 1 (top connector) | Un-P1-C7-T1 | No |
GX Dual-Port 12X Channel Attach adapter controller slot 2 port 2 (bottom connector) | Un-P1-C7-T2 | No |
Vortex RAID Auxiliary Card | Un-P1-C10 | Yes |
RAID card battery | Un-P1-C10-E1 | No |
Dagger RAID Base Card | Un-P1-C11 | Yes |
Thermal management card | Un-P1-C12 | Yes |
Memory modules | ||
Memory module 1 on processor 1 | Un-P1-C13-C2 | Yes |
Memory module 2 on processor 1 | Un-P1-C13-C3 | Yes |
Memory module 3 on processor 1 | Un-P1-C13-C4 | Yes |
Memory module 4 on processor 1 | Un-P1-C13-C5 | Yes |
Memory module 5 on processor 1 | Un-P1-C13-C6 | Yes |
Memory module 6 on processor 1 | Un-P1-C13-C7 | Yes |
Memory module 7 on processor 1 | Un-P1-C13-C8 | Yes |
Memory module 8 on processor 1 | Un-P1-C13-C9 | Yes |
Memory module 1 on processor 2 | Un-P1-C14-C2 | Yes |
Memory module 2 on processor 2 | Un-P1-C14-C3 | Yes |
Memory module 3 on processor 2 | Un-P1-C14-C4 | Yes |
Memory module 4 on processor 2 | Un-P1-C14-C5 | Yes |
Memory module 5 on processor 2 | Un-P1-C14-C6 | Yes |
Memory module 6 on processor 2 | Un-P1-C14-C7 | Yes |
Memory module 7 on processor 2 | Un-P1-C14-C8 | Yes |
Memory module 8 on processor 2 | Un-P1-C14-C9 | Yes |
Memory module 1 on processor 3 | Un-P1-C15-C2 | Yes |
Memory module 2 on processor 3 | Un-P1-C15-C3 | Yes |
Memory module 3 on processor 3 | Un-P1-C15-C4 | Yes |
Memory module 4 on processor 3 | Un-P1-C15-C5 | Yes |
Memory module 5 on processor 3 | Un-P1-C15-C6 | Yes |
Memory module 6 on processor 3 | Un-P1-C15-C7 | Yes |
Memory module 7 on processor 3 | Un-P1-C15-C8 | Yes |
Memory module 8 on processor 3 | Un-P1-C15-C9 | Yes |
Memory module 1 on processor 4 | Un-P1-C16-C2 | Yes |
Memory module 2 on processor 4 | Un-P1-C16-C3 | Yes |
Memory module 3 on processor 4 | Un-P1-C16-C4 | Yes |
Memory module 4 on processor 4 | Un-P1-C16-C5 | Yes |
Memory module 5 on processor 4 | Un-P1-C16-C6 | Yes |
Memory module 6 on processor 4 | Un-P1-C16-C7 | Yes |
Memory module 7 on processor 4 | Un-P1-C16-C8 | Yes |
Memory module 8 on processor 4 | Un-P1-C16-C9 | Yes |
Device physical locations | ||
Half high SAS Tape Device | Un-P2-D1 | No |
Slim DVD | Un-P2-D2 | No |
SFF Disk drive 1 | Un-P2-D3 | Yes |
SFF Disk drive 2 | Un-P2-D4 | Yes |
SFF Disk drive 3 | Un-P2-D5 | Yes |
SFF Disk drive 4 | Un-P2-D6 | Yes |
SFF Disk drive 5 | Un-P2-D7 | Yes |
SFF Disk drive 6 | Un-P2-D8 | Yes |
SFF Disk drive 7 | Un-P2-D9 | Yes |
SFF Disk drive 8 | Un-P2-D10 | Yes |
Control panel | ||
LightPath Operator Panel | Un -D1 | No |
Temperature sensor | Un -D1 | No |
Server firmware | ||
Platform firmware | Um-Y1 | |
System | Um |