两种方法:
1.
FORM alv_user_command USING p_ucomm LIKE sy-ucomm rs_selfield TYPE slis_selfield.
PERFORM alv_refresh CHANGING rs_selfield-col_stable
rs_selfield-row_stable
rs_selfield-refresh.
ENDFORM.
FORM alv_refresh CHANGING po_col_stable po_row_stable po_refresh.
po_col_stable = 'X'.
po_row_stable = 'X'.
po_refresh = 'X'.
ENDFORM.
2.
FORM alv_user_command USING p_ucomm LIKE sy-ucomm rs_selfield TYPE slis_selfield.
DATA gv_grid TYPE REF TO cl_gui_alv_grid.
CALL FUNCTION 'GET_GLOBALS_FROM_SLVC_FULLSCR'
IMPORTING
e_grid = gv_grid.
CALL METHOD gv_grid->check_changed_data.
rs_selfield-refresh = 'X'.
ENDFORM.