机器环境
系统版本:Windows Server2012
硬件型号:HP ProLiant DL380 G6
**HP ProLiant Array Configuration Utility (CLI)**信息查看
1.下载安装
https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_33fe6fcf4fcb4beab8fee4d2dc
打不开自己想办法科学访问
2.使用帮助
安装之后进入阵列配置界面hpacucli
查看阵列卡与硬盘状态信息
=>
=> ctrl all show status #查看阵列卡槽位
Smart Array P410i in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
=> ctrl slot=0 show config detail #查看阵列卡信息
Smart Array P410i in Slot 0 (Embedded) #阵列卡信息
Bus Interface: PCI
Slot: 0
Serial Number: 50123456789ABCDE
Cache Serial Number: PAAVP9SYH77X
RAID 6 (ADG) Status: Disabled
Controller Status: OK
略…………
Array: A #阵列A信息
Interface Type: SAS
Unused Space: 0 MB
Status: OK
略…………
Array: B #阵列B信息
Interface Type: SAS
Unused Space: 0 MB
Status: OK
略…………
unassigned #未配置硬盘
略…………
=> controller slot=0 logicaldrive all show #查看当前RAID
Smart Array P410i in Slot 0 (Embedded)
array A
logicaldrive 1 (136.7 GB, RAID 1, OK)
array B
logicaldrive 2 (410.1 GB, RAID 1+0, OK)
=> ctrl slot=0 pd all show status #查看硬盘健康状态
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 146 GB): OK
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 146 GB): OK
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 146 GB): OK
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, 146 GB): OK
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, 146 GB): OK
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, 146 GB): OK
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, 146 GB): Predictive Failure #这块盘故障
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, 146 GB): OK
3.收集故障硬盘报告<hp售后要这个报告>
=> ctrl all diag file=/home/HP_DL380_G6.zip
Generating diagnostic report...done
done
=> exit
参考: