MegaCli Common Commands

MegaCli Common Commands

On this page

  • General Parameters
  • Gather information
  • Controller management
  • Virtual drive management
  • Physical drive management
  • Hot spare management
  • Walkthrough: Rebuild a Drive that is marked 'Foreign' when Inserted:
  • Walkthrough: Change/replace a drive

General Parameters

  • Adapter parameter -aN

The parameter -aN (where N is a number starting with zero or the string ALL) specifies the adapter ID. If you have only one controller it’s safe to use ALL instead of a specific ID, but you’re encouraged to use the ID for everything that makes changes to your RAID configuration.

  • Physical drive parameter      -PhysDrv [E:S]

For commands that operate on one or more pysical drives, the -PhysDrv [E:S] parameter is used, where E is the enclosure device ID in which the drive resides and S the slot number (starting with zero). You can get the enclosure device ID using MegaCli -EncInfo -aALL. The E:S syntax is also used for specifying the physical drives when creating a new RAID virtual drive (see 5).

  • Virtual drive parameter -Lx

The parameter -Lx is used for specifying the virtual drive (where x is a number starting with zero or the string all).

Running the executable can be accomplished by:

shell> /opt/MegaRAID/MegaCli/MegaCli <cmd>

or

shell> cd /opt/MegaRAID/MegaCli
shell> ./MegaCli <cmd>

Gather information

  • Controller information

     MegaCli -AdpAllInfo -aALL
     MegaCli -CfgDsply -aALL
     MegaCli -adpeventlog -getevents -f lsi-events.log -a0 -nolog

  • Enclosure information

     MegaCli -EncInfo -aALL

  • Virtual drive information

     MegaCli -LDInfo -Lall -aALL

  • Physical drive information

     MegaCli -PDList -aALL
     MegaCli -PDInfo -PhysDrv [E:S] -aALL

  • Battery backup information      (Cisco MSPs do not have the battery backup unit installed, but in case yours has one)

     MegaCli -AdpBbuCmd -aALL 

  • Check Battery backup warning on boot.  If this is enabled on an MSP, it will require manual intervention every time the system boots
     MegaCli -AdpGetProp BatWarnDsbl -a0 
     

Controller management

  • Silence active alarm

     MegaCli -AdpSetProp AlarmSilence -aALL

  • Disable alarm

     MegaCli -AdpSetProp AlarmDsbl -aALL

  • Enable alarm

     MegaCli -AdpSetProp AlarmEnbl -aALL 

  • Disable battery backup warning on system boot

     MegaCli -AdpSetProp BatWarnDsbl -a0

  • Change the adapter rebuild rate to 60%:

     MegaCli -AdpSetProp {RebuildRate -60} -aALL

Virtual drive management

  • Create RAID 0, 1, 5 drive

     MegaCli -CfgLdAdd -r(0|1|5) [E:S, E:S, ...] -aN

  • Create RAID 10 drive

     MegaCli -CfgSpanAdd -r10 -Array0[E:S,E:S] -Array1[E:S,E:S] -aN

  • Remove drive

     MegaCli -CfgLdDel -Lx -aN 

Physical drive management

  • Set state to offline

     MegaCli -PDOffline -PhysDrv [E:S] -aN

  • Set state to online

     MegaCli -PDOnline -PhysDrv [E:S] -aN

  • Mark as missing

     MegaCli -PDMarkMissing -PhysDrv [E:S] -aN

  • Prepare for removal

     MegaCli -PdPrpRmv -PhysDrv [E:S] -aN

  • Replace missing drive

     MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
     

The number N of the array parameter is the Span Reference you get using MegaCli -CfgDsply -aALL and the number N of the row parameter is the Physical Disk in that span or array starting with zero (it’s not the physical disk’s slot!).

  • Rebuild drive - Drive status should be "Firmware state: Rebuild"

     MegaCli -PDRbld -Start -PhysDrv [E:S] -aN
     MegaCli -PDRbld -Stop -PhysDrv [E:S] -aN
     MegaCli -PDRbld -ShowProg -PhysDrv [E:S] -aN     
     MegaCli -PDRbld -ProgDsply -physdrv [E:S] -aN

  • Clear drive

     MegaCli -PDClear -Start -PhysDrv [E:S] -aN
     MegaCli -PDClear -Stop -PhysDrv [E:S] -aN
     MegaCli -PDClear -ShowProg -PhysDrv [E:S] -aN

  • Bad to good

     MegaCli -PDMakeGood -PhysDrv[E:S] -aN

     Changes drive in state Unconfigured-Bad to Unconfigured-Good.

Hot spare management

  • Set global hot spare

     MegaCli -PDHSP -Set -PhysDrv [E:S] -aN
   
  • Remove hot spare

     MegaCli -PDHSP -Rmv -PhysDrv [E:S] -aN
   
  • Set dedicated hot spare

     MegaCli -PDHSP -Set -Dedicated -ArrayN,M,... -PhysDrv [E:S] -aN 

Walkthrough: Rebuild a Drive that is marked 'Foreign' when Inserted:

 
  • Bad to good
    MegaCli -PDMakeGood -PhysDrv [E:S]  -aALL

  • Clear the foreign setting

     MegaCli -CfgForeign -Clear -aALL

 
  • Set global hot spare
     MegaCli -PDHSP -Set -PhysDrv [E:S] -aN

Walkthrough: Change/replace a drive

1. Set the drive offline, if it is not already offline due to an error

     MegaCli -PDOffline -PhysDrv [E:S] -aN

2. Mark the drive as missing

     MegaCli -PDMarkMissing -PhysDrv [E:S] -aN
  

3. Prepare drive for removal

     MegaCli -PDPrpRmv -PhysDrv [E:S] -aN
  

4. Change/replace the drive

5. If you’re using hot spares then the replaced drive should become your new hot spare drive

     MegaCli -PDHSP -Set -PhysDrv [E:S] -aN
  

6. In case you’re not working with hot spares, you must re-add the new drive to your RAID virtual drive and start the rebuilding

     MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
     MegaCli -PDRbld -Start -PhysDrv [E:S] -aN