DS5020磁盘impending failure故障处理

博客详细记录了一起DS5020磁盘出现Impending Failure警告,随后导致Drive failure并进行重建的过程。在控制器日志中,Enclosure 85, Slot 9的磁盘被标记为失败,而Enclosure 85, Slot 16的热备磁盘开始重建,并最终完成。尽管Storage Manager仍显示故障状态,但建议直接更换问题磁盘,注意兼容性并遵循特定更换流程,包括等待Copyback完成,确保磁盘状态转为Optimal。" 124374979,12205319,Mybatis-plus 快速入门与基本操作,"['Java', 'Mybatis', 'Mybatis-plus', '数据库连接', 'ORM框架']
摘要由CSDN通过智能技术生成

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23228

Event type: 101E

Event category: Error

Priority: Critical

Event needs attention: true

Event send alert: true

Event visibility: true

Description: Impending drive failure detected by controller

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23230

Event type: 1012

Event category: Error

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Destination driver error

Event specific codes: 204/3/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23231

Event type: 6008

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Stable storage drive unusable

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23232

Event type: 2226

Event category: Internal

Priority: Informational

Event needs attenti