to advance the output trail sequence past the current trail sequence number, then restart. Then, use ALTER EXTSEQNO on the s
ubsequent pump EXTRACT, or REPLICAT, process group to start reading from the new trail file created by ALTER ETROLLOVER; the
downstream process will not automatically switch to the new trail file.
在初始化的时候,由于容灾端没有准备就绪,生产端来回进行了很多次的操作,导致生产端抽取混乱,此时在进行RMAN之前,重新启动抽取,忽略调之前的混乱信息。
解决办法:
alter extract xxx,etrollover
--------------------------------------------------------------------------------------------------
GGSCI (rac1) 16> alter extract eora,etrollover
2012-05-29 20:34:15 INFO OGG-01520 Rollover performed. For each affected output trail of Version 10 or higher format, after starting the source extract, issue ALTER EXTSEQNO for that trail's reader (either pump EXTRACT or REPLICAT) to move the reader's scan to the new trail file; it will not happen automatically.
EXTRACT altered.
GGSCI (rac1) 18> start eora
Sending START request to MANAGER ...
EXTRACT EORA starting
GGSCI (rac1) 26> info all
Program Status Group Lag Time Since Chkpt
MANAGER RUNNING
EXTRACT RUNNING EORA 00:00:00 00:00:11
EXTRACT RUNNING PUMP_SO 00:00:00 00:15:59