From: http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdmala_dc_act_pdp_cont_rej.php
The causes are specified in 3GPP TS 24.008 10.5.6.6.
Cause Value (decimal) | Cause Value (bits) | Cause |
---|---|---|
25 | 00011001 | LLC or SNDCP Failure |
26 | 00011010 | Insufficient Resources |
27 | 00011011 | Missing or Unknown APN |
28 | 00011100 | Unknown PDP Address or PDP Type |
29 | 00011101 | User Authentication Failed |
30 | 00011110 | Activation Rejected By GGSN |
31 | 00011111 | Activation Rejected, Unspecified |
32 | 00100000 | Service Option Not Supported |
34 | 00100010 | Service Opt Temporarily Out of Order |
35 | 00100011 | NSAPI Already Used |
36 | 00100100 | Regular Deactivation |
37 | 00100101 | QoS Not Accepted |
38 | 00100110 | Network Failure |
39 | 00100111 | Reactivation Required |
40 | 00101000 | Feature Not Supported |
41 | 00101001 | Semantic Error in TFT Operation |
42 | 00101010 | Syntactical Error in TFT Operation |
43 | 00101011 | Unknown PDP Context |
44 | 00101100 | Semantic Error in Packet Filter(s) |
45 | 00101101 | Syntactical Errors in Packet Filters(s) |
46 | 00101110 | PDP Context Without TFT Already Activated |
81 | 01010001 | Invalid Transaction Identifier Value |
95 | 01011111 | Semantically Incorrect Message |
96 | 01100000 | Invalid Mandatory Information |
97 | 01100001 | Msg Type Non-existent/Not Implemented |
98 | 01100010 | Msg Type Not Compatible With Protocol State |
99 | 01100011 | IE Non-existent or Not Implemented |
100 | 01100100 | Conditional IE Error |
111 | 01101111 | Protocol Error, Unspecified |