EMC LUN ON HP UNIX盘符不一致的解决方法
1.同一块LUN;找出对应盘符的唯一ID,并找出其WWN
cd /dev/rdisk
节点1
# ls -l /dev/rdisk/disk161
crw-r--r-- 1 root sys 13 0x000030 Aug 20 13:53 /dev/rdisk/disk161
节点2
# ls -l /dev/rdisk/disk162
crw-r--r-- 1 root sys 13 0x000034 Aug 20 13:53 /dev/rdisk/disk162
2.创建新的盘符,并设置成双节点一致
cd /dev/rdisk
节点1
mknod /dev/rdisk/disk163 c 13 0x000030 <=唯一的
节点2
mknod /dev/rdisk/disk163 c 13 0x000034 <=唯一的
3.验证盘符是否一致
节点1
# ioscan -funN -C disk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
disk 161 64000/0xfa00/0x30 esdisk CLAIMED DEVICE DGC RAID 5
/dev/disk/disk161 /dev/rdisk/disk163
节点2
# ioscan -funN -C disk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
disk 162 64000/0xfa00/0x34 esdisk CLAIMED DEVICE DGC RAID 5
/dev/disk/disk162 /dev/rdisk/disk163
##注意:2个节点的/dev/disk是有所有不同的,一个是disk161,一个是disk162,所以如果需要使用/dev/disk一定要注意哦。##
3-1.使用powermt验证
命令: powermt display dev=all
节点1
# powermt display dev=all
Pseudo name=disk163
VNX ID=FCN00114900102 [collection_sg]
Logical device ID=6006016045D02E00FA8E1E687A26E411 [cdc_hp]
state=alive; policy=CLAROpt; queued-IOs=0
Owner: default=SP A, current=SP A Array failover mode: 4
==============================================================================
--------------- Host --------------- - Stor - -- I/O Path -- -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1 0/6/0/0/0/0/2/0/0/1.0x5006016c47200986.0x7000000000000 c9t0d7 SP B4 active alive 0 0
1 0/6/0/0/0/0/2/0/0/1.0x5006016447200986.0x7000000000000 c7t0d7 SP A4 active alive 0 0
0 0/6/0/0/0/0/2/0/0/0.0x5006016847200986.0x7000000000000 c5t0d7 SP B0 active alive 0 0
0 0/6/0/0/0/0/2/0/0/0.0x5006016047200986.0x7000000000000 c3t0d7 SP A0 active alive 0 0
节点2
# powermt display dev=all
Pseudo name=disk163
VNX ID=FCN00114900102 [collection_sg]
Logical device ID=6006016045D02E00FA8E1E687A26E411 [cdc_hp]
state=alive; policy=CLAROpt; queued-IOs=0
Owner: default=SP A, current=SP A Array failover mode: 4
==============================================================================
--------------- Host --------------- - Stor - -- I/O Path -- -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1 0/6/0/0/0/0/2/0/0/1.0x5006016c47200986.0x7000000000000 c9t0d7 SP B4 active alive 0 0
1 0/6/0/0/0/0/2/0/0/1.0x5006016447200986.0x7000000000000 c7t0d7 SP A4 active alive 0 0
0 0/6/0/0/0/0/2/0/0/0.0x5006016847200986.0x7000000000000 c5t0d7 SP B0 active alive 0 0
0 0/6/0/0/0/0/2/0/0/0.0x5006016047200986.0x7000000000000 c3t0d7 SP A0 active alive 0 0
##注意:千万不要使用这个命令insf -e,此命令会继续使用系统默认的重命名,如果重命名后盘符就又不一致了。##
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/26442936/viewspace-1255009/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/26442936/viewspace-1255009/