Buffer I/O error on device sdh

一台Dell 6950服务器频繁出现'Buffer I/O error on device sdh'错误,导致无法读取分区表。通过检查emc设备、scsi设备,发现问题是Linux将虚拟软驱识别为sdh设备。解决方法是登录DRAC,取消附加虚拟介质的设置,关闭虚拟软驱。
摘要由CSDN通过智能技术生成

一台dell 6950机器突然不断地报

Jun 26 20:54:46 asoftdw_pri kernel: sdh : READ CAPACITY failed.

Jun 26 20:54:46 asoftdw_pri kernel: sdh : status=0, message=00, host=7, driver=00

Jun 26 20:54:46 asoftdw_pri kernel: sdh : sense not available.

Jun 26 20:55:16 asoftdw_pri kernel: sdh: Write Protect is off

Jun 26 20:55:16 asoftdw_pri kernel: sdh: assuming drive cache: write through

Jun 26 20:55:16 asoftdw_pri kernel: sdh:<3>Buffer I/O error on device sdh, logical block 0

Jun 26 20:55:16 asoftdw_pri kernel: Buffer I/O error on device sdh, logical block 0

Jun 26 20:55:16 asoftdw_pri kernel: Buffer I/O error on device sdh, logical block 0

Jun 26 20:55:16 asoftdw_pri kernel: unable to read partition table

这样的错误。

[@more@]

Fdisk -l也是hang在那里。

Df -h看不到sdh的设备。

由于上面挂了emccx3-80,所以查看emc的设备:

root@asoftdw_pri:/var/log> powermt display dev=all

Pseudo name=emcpowerb

CLARiiON ID=CK200071101314 [Storage Group 1]