机架存放 (Rack Storage)

主要特点: (Main features:)

  • Minimum dimensions: 800 x 800 mm Height: 42U (2080 mm)

    最小尺寸:800 x 800毫米高度:42U(2080毫米)
  • At least 2 depth adjustable

    至少2个深度可调
  • Lexan door complete with lock

    Lexan门配有锁
  • Side panels removable lock with special key

    侧板可移动锁,带特殊钥匙
  • Rear panel made of sheet steel, with key lock

    钢板制成的后面板,带钥匙锁
  • Dual power supply line, each completely independent and connected to emergency generator.

    双电源线,每个电源线完全独立,并连接到应急发电机。
  • Copper bar, long 1800 mm for the grounding of all equipment installed in the closet, properly fitted

    铜棒,长1800 mm,用于将壁橱中安装的所有设备正确接地
  • Filter ventilation cabinet which must include the 15W fans, cable, metal grill, outdoor grill, silhouette sticker, decal sheet, screws, and support for the filter.

    过滤器通风柜,必须包括15W风扇,电缆,金属格栅,室外格栅,轮廓贴纸,贴花纸,螺钉和过滤器支架。
  • Environmental control systems with leakage, temperature, water, smoke, fire and intrusion notification via audible and SMTP and TCP / IP and countermeasures with anti-flooding

    环境控制系统,通过声音,SMTP和TCP / IP通知泄漏,温度,水,烟,火和入侵,并采取防洪措施
  • Dual power supply and power interruption of the first circuit breaker upstream of the rack

    机架上游的第一个断路器的双电源和电源中断
  • The reporting of non-availability of services

    报告服务不可用
  • 4 standard closet shelves

    4个标准壁橱架

The cabinet contains, for example, from top to bottom:

机柜包含例如从上到下的内容:

  • The suction on the filter

    过滤器上的吸力
  • The power supply

    电源供应
  • 2U Void

    2U虚空
  • The data and voice panels interspersed with guides for cables and rings with proper guidance.

    数据和语音面板散布着电缆和环的导向,并带有适当的导向。
  • 1U Empty

    1U空
  • Apparatus network

    仪器网络
  • Patch the PBX

    修补PBX
  • 4U Empty

    4U空
  • Central Management Server

    中央管理服务器
  • XU * Empty placed with the 4 shelves

    XU *空放置,带4个架子
  • UPS in its lowest position possible.

    UPS处于最低位置。

This cabinet is connected to ground through the bar and not using the dedicated earthing the electrical system.

该机柜通过拉杆接地,不使用电气系统专用接地。

数据和语音面板的组织 (Organization of data and voice panels)

The data and voice panels are the panels where the cables come ctg6 LFZH coatings that come from taking the structure, the cables are properly placed to the gooseneck on the side of the cabinet and panels must be fitted with patches Cord Cat.6 LFZH coatings to maximize order and cleanliness in terms of organization also changes later. In the lower plate are the doors to the outside of the building, garden and taken for the fiber to the wing of future construction.

数据和语音面板是电缆的面板,该电缆来自于结构取用的ctg6 LFZH涂层,电缆已正确放置在机柜侧面的鹅颈上,并且面板必须安装有跳线Cat.6 LFZH涂层在组织方面最大化秩序和清洁度也会在以后发生变化。 在下面的板中是通往建筑物,花园外部的门,并将其作为光纤传送到未来建筑的机翼。

The top plates will be placed on the ground floor the doors just below those of the first floor and on top of all the plates on the second floor. In no case should never happen in a single plate are placed on doors on different floors

顶板将放在一楼的门正下方,在第二层的所有板的顶部。 在任何情况下都绝不能将一块盘子放在不同楼层的门上

In each plate is organized strictly in alphabetical order, the door is positioned at the door 1SA5 1SA4 1SB1 and before the door. The doors are placed before the doors 1Cxxx 1Sxxx

在严格按照字母顺序组织的每个板中,门位于门1SA5 1SA4 1SB1以及门的前面。 门放在门1Cxxx 1Sxxx之前

每个门带有以下标识: (Each door bears the following identification:)

NumeroPiano ID + + environment numeropresa

Numero钢琴ID + +环境numeropresa

The floors are numbered as: 0) ground floor (outdoor environments are the exception and have ID Plan E) 1) Close 2) Second floor, etc.

楼层编号为: 0)底层(室外环境是例外,并且具有ID计划E)1)封闭2)第二层,依此类推。

环境标识符是: (Environment identifiers are:)

  • Rooms: S + idStanza (eg SA, SB, etc.) Id where the room is not only for indoor corridor. The meeting room is a room

    房间:S + idStanza(例如SA,SB等)的ID,该房间不仅用于室内走廊。 会议室是一个房间
  • Corridors: C for the corridors and any other building other than a room like the gatehouse or reception desk

    走廊:C,用于走廊和除门房或接待室等房间以外的其他任何建筑物
  • Inside: E + idPresa sockets outdoors according to this convention:

    内部:E + idPresa按照以下惯例在户外插座:

= 0 or fiber optic = 1-99 or RJ45 sockets on the perimeter of the building with numbers increasing clockwise starting from the front door of the building, from top to bottom. 100 = reserved or number not assigned or 101 = RJ45 sockets on the external perimeter and in the garden

= 0或光纤=建筑物外围的1-99或RJ45插座,编号从建筑物的前门开始,从上到下顺时针递增。 100 =保留或未分配编号,或者101 =外围和花园中的RJ45插座

在走廊和房间的出口上是这样标记的: (In the corridors and rooms outlets are marked in this way:)

  • In the rooms taking one is that, with your back to the front door is on the left, the others are numbered clockwise

    在房间中,一个是您的,您的后门回到左侧,左侧是其他,顺时针编号
  • In the corridors the socket 1 is that giving back to the door of the lift, is on the left, the others are numbered clockwise, from top to bottom.

    在走廊中,插座1是左侧的回升电梯门,其余的插座则从上到下顺时针编号。

For example:

例如:

  • 1SA4 is taking 4 of the room to the first floor (1)

    1SA4正在将4个房间移至第一层(1)
  • 0C6 is the socket 6 in the lobby or hallway on the ground floor

    0C6是位于底层大厅或走廊中的插槽6
  • E101 is the port closest to the entrance gate clockwise

    E101是顺时针方向最靠近入口大门的端口
  • E1 is the port closest entrance of the building, higher clockwise

    E1是建筑物最近的港口入口,顺时针方向较高
  • E0 is taken for future fiber optic

    E0被认为是未来的光纤

Each socket in rooms and corridors should be marked with their identification number that matches the identification number affixed to the respective outlet plate cabinet commute to quickly identify any faults or changes to be made.

房间和走廊中的每个插座都应标有其识别号,该识别号应与相应的出口板柜通勤时粘贴的识别号相匹配,以快速识别任何故障或要进行的更改。

For labeling of the external sockets to be given special care so that external agents can make labels unreadable, we recommend the use of labels in relief and / or welded.

为了特别注意外部插座的标签,以便外部代理可以使标签不可读,我们建议使用浮雕和/或焊接的标签。

网络设备 (The network device)

It is intended as an apparatus of a network switch that ensures high security, reliability and scalability and allows easy subsequent software upgrade.

它旨在用作确保高安全性,可靠性和可伸缩性并允许轻松进行后续软件升级的网络交换机。

It will be implemented so the intelligent network services such as QoS (Quality of Service), advanced traffic prioritization, security filters, and multicast management to the network perimeter while maintaining the ease of traditional LAN switching.

它将实现为智能网络服务,例如QoS(服务质量),高级流量优先级,安全过滤器和对网络外围的多播管理,同时保持传统LAN交换的简便性。

The switch could for instance have 24 10/100 ports for desktop connections and 2 GBIC-based Gigabit Ethernet ports (Gigabit Interface Converter) that currently allow you to install a type of configuration for the stack and the uplink and to reserve for the future ability to migrate to other configurations.

例如,该交换机可能具有24个用于桌面连接的10/100端口和2个基于GBIC的千兆以太网端口(千兆位接口转换器),这些端口当前允许您为堆栈和上行链路安装一种类型的配置,并为将来的功能保留迁移到其他配置。

The apparatus must be equipped with redundant power supply directly connected to the mains, the main power supply is connected to the UPS instead.

设备必须配备直接连接到市电的冗余电源,而主电源则连接到UPS。

PBX的排列 (Permutations of the PBX)

It is good to realize that permit, also include the telephone inside the cabinet. In this case it would be good to choose a PBX equipped on the front panel, all the necessary sockets and in particular the RJ45 sockets for connecting lines and internal and USB sockets, RS232, audio input for music on hold PBX etc. ..

最好认识到许可证,还包括机柜内的电话。 在这种情况下,最好选择前面板上配备的PBX,所有必需的插座,尤其是用于连接线路的RJ45插座以及内部和USB插座,RS232,用于保留PBX的音乐的音频输入等。

Also this apparatus must be equipped with redundant power supply directly connected to the mains. The main power supply is connected to the UPS instead.

此设备还必须配备直接连接到主电源的冗余电源。 主电源改为连接到UPS。

中央管理服务器 (Central Management Server)

The apparatus must be equipped with redundant power supply directly connected to the mains. The main power supply is connected to the UPS instead.

该设备必须配备直接连接到主电源的冗余电源。 主电源改为连接到UPS。

UPS (UPS)

The choice of UPS is best done in the name of scalability of runtimes so that we can extend and optimize the application through the use of matching battery packs. Initially, modules will be available enough to ensure one hour of battery equipment found in the closet.

UPS的选择最好以运行时间的可扩展性为名,以便我们可以通过使用匹配的电池组来扩展和优化应用程序。 最初,模块将足够可用,以确保在壁橱中找到一小时的电池设备。

EDC中的安全性和隐私 (Security and privacy in the EDC)

To fulfill the new code regulations for privacy and security laws must operate on both the computerized by installing the necessary protection hardware and software that the appearance of active and passive safety of the place through the services provided by systems environmental alarm and peripheral.

为了满足新的隐私和安全法法规,必须通过安装必要的保护硬件和软件在计算机上运行,​​该保护硬件和软件通过系统环境警报和外围设备提供的服务来显示场所的主动和被动安全外观。

环境与设备 (Environmental and device)

You should install an alarm system and security with Central dialer network with mixed analog / GSM and anti-tamper security sabotage.

您应该使用带有混合模拟/ GSM和防篡改安全性的中央拨号器网络安装警报系统和安全性。

The alarm system operates outside of the building using inertial sensors and magnetic sensors mounted on doors and windows inside the building is controlled through the use of volumetric and acoustic sensors. All sensors must be equipped with security controlled by the Central tumper.

警报系统使用惯性传感器在建筑物外部运行,而安装在建筑物内门窗上的磁性传感器则通过使用体积和声音传感器进行控制。 所有传感器都必须配备由中央转鼓控制的安全装置。

You must provide the structure of CCTV cameras and full lighting controlled by motion sensors. The cameras, type compatible with TCP / IP are connected directly to the data network also allows remote control of the situation.

您必须提供CCTV摄像机的结构以及由运动传感器控制的完整照明。 与TCP / IP兼容的摄像机类型直接连接到数据网络,也可以对情况进行远程控制。

To control beyond the limits of the property is necessary require special permission according to the laws and regulations.

要控制超出财产范围的限制,必须根据法律法规获得特别许可。

Access to property is regulated through the use of badges: these access control systems provide the ability to allow passage to persons authorized by a reading device or through voice recognition door entry and allow you to record and verify the transits made.

通过使用证章来控制财产的进入:这些访问控制系统提供了允许通过阅读设备或通过语音识别门进入授权人员的通道,并允许您记录和验证所进行的过境。

远程信息处理 (Telematics)

You should install a hardware firewall upstream Internet connection to monitor and manage traffic entering and leaving the network.

您应该在上游Internet连接上安装硬件防火墙,以监视和管理进入和离开网络的流量。

The wireless network must also be equipped with WEP security (if it is not possible to rely on WPA), MAC Address Control and Radius authentication server or an IDS.

无线网络还必须配备WEP安全性(如果不可能依靠WPA),MAC地址控制和Radius身份验证服务器或IDS。

Study: From Wikipedia, the free encyclopedia. The text is available under the Creative Commons.

研究:来自维基百科,免费的百科全书。 该文本可在“ 知识共享”下找到

翻译自: https://www.eukhost.com/blog/webhosting/the-data-processing-center-information-part-4/

单片机数据处理部分

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值