linux内核启动后出现:
BusyBox v1.18.4 (2011-03-22 14:01:42 CST) multi-call binary.
Usage: getty [OPTIONS] BAUD_RATE TTY [TERMTYPE]
Open a tty, prompt for a login name, then invoke /bin/login
Options:
-h Enable hardware (RTS/CTS) flow control
-i Don't display /etc/issue before running login
-L Local line, don't do carrier detect
-m Get baud rate from modem's CONNECT status message
-w Wait for a CR or LF before sending /etc/issue
-n Don't prompt the user for a login name
-f ISSUE_FILE Display ISSUE_FILE instead of /etc/issue
-l LOGIN Invoke LOGIN instead of /bin/login
-t SEC Terminate after SEC if no username is read
-I INITSTR Send INITSTR before anything else
-H HOST Log HOST into the utmp file as the hostname
INIT: Id "con" respawning too fast: disabled for 5 minutes
原因:不能获得此时console的baudrate,所以,不断打印重复信息,导致init进程将其disable for 5min。
解决:
/etc/inittab中,
将
con:2345:respawn:/sbin/getty console
改为
con:2345:respawn:/sbin/getty 115200 console