HP ProLiant 服务器 - POST 错误消息和蜂鸣代码(8)1700 系列错误消息

HP ProLiant 服务器 - POST 错误消息和蜂鸣代码(8)1700 系列错误消息
2011年05月25日
  1700 系列错误消息1711 错误消息 #1[b]错误消息:[/b]
  [b]1711-Slot Z Drive Array - RAID ADG Logical Drive(s) Configured but Array Accelerator Size 内存 安装阵列加速器内存模块。
  [b]操作:[/b]
  不建议此配置。 将逻辑驱动器迁移到 RAID 5,或升级至更大的阵列加速器模块。
  1711 错误消息 #2[b]错误消息:[/b]
  [b]1711-Slot z Drive Array - Stripe size too large for RAID 5/6 logical drive(s). ...This configuration is not recommended due to transfer buffer usage.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  针对创建的 Raid 5/6 逻辑驱动器的容量的 Raid 配置不正确。
  [b]操作:[/b]
  由于控制器内存的要求,不建议此配置。 执行 RAID 迁移,以使用阵列配置实用程序降低条带大小。
  1712 错误消息[b]错误消息:[/b]
  [b]1712 - Slot X Drive Array - RAID 5 logical drive(s) configured with XX Drives, but Array Accelerator Size 内存发生故障。
  [b]操作:[/b]
  如果问题仍然存在,请更换控制器。
  1716 错误消息[b]错误消息:[/b]
  [b]1716-Slot z Drive Array Controller - Unrecoverable Media Errors Detected on Drives[/b]
  [b]...Errors will be fixed automatically when these sectors are overwritten. Backup and restore recommended.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到驱动器上的介质错误而且不能纠正,这是因为降级的容错或介质错误位于相同阵列中另一个驱动器的相同位置。 当读取该块地址时,不可恢复的读错误将返回至操作系统。
  [b]操作:[/b]
  备份并恢复驱动器上的数据。 对受影响的块执行连续写入操作可解决介质错误。
  1717 错误消息[b]错误消息:[/b]
  [b]1717-Slot z Drive Array Controller - Disk Drive(s) Reporting OVERHEATED Condition[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  消息中所列的阵列驱动器当前处于过热的状态。
  [b]操作:[/b]
  操作: 检查风扇,确保气流可流经驱动器。 安装检修板。
  1718 错误消息[b]错误消息:[/b]
  [b]1718-Slot z Drive Array Controller - Device discovery found more devices attached to this controller than firmware currently supports...[/b]
  [b]...Some devices are ignored.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  固件不支持当前连接到控制器的设备的数量。
  [b]操作:[/b]
  如果版本注释中指出已经添加了针对额外设备的支持,请升级到最新的控制器固件版本。去除连接到控制器上的某些设备。
  1719 错误消息[b]错误消息:[/b]
  [b]1719-Slot z Drive Array - A controller failure event occurred prior to this power-up (previous lock-up code = 0x####)[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  服务器启动前控制器出现故障。
  [b]操作:[/b]
  安装最新的控制器固件版本。 如果问题仍然存在,请更换控制器。
  1720 错误消息 #1[b]错误消息:[/b]
  [b]1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID Z.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到硬盘 SMART 潜在故障。 硬盘可能会在未来发生故障。
  [b]操作:[/b]
  如果该硬盘属于非容错配置的一部分,请备份所有数据,然后更换硬盘并恢复所有数据。如果该硬盘属于容错配置的一部分,那么在阵列中的所有其它硬盘在线之前不要更换该硬盘。
  1720 错误消息 #2[b]错误消息:[/b]
  [b]1720-S.M.A.R.T. Hard Drive Detects Imminent Failure[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到硬盘 SMART 潜在故障。 硬盘可能会在未来发生故障。
  [b]操作:[/b]
  如果配置为非 RAID 0 阵列,请更换故障硬盘和即将发生故障的硬盘。请参阅服务器文档。如果配置为 RAID 0 阵列或非 RAID 设置,备份并更换硬盘,然后恢复系统。
  1721 错误消息[b]错误消息:[/b]
  [b]1721-Slot X Drive Array - Drive Parameter Tracking Predicts Imminent Failure...[/b]
  [b]...The following devices should be replaced when conditions permit. Do not replace drive unless all other drives in the array are on-line! Back up data before replacing drive(s) if using RAID 0.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  驱动器参数追踪报告指定硬盘中的潜在故障。 驱动器可能会在未来发生故障。
  [b]操作:[/b]
  如果该硬盘属于非容错配置的一部分,请备份所有数据,然后更换硬盘并恢复所有数据。如果该硬盘属于容错配置的一部分,那么在阵列中的所有其它硬盘在线之前不要更换该硬盘。
  1724 错误消息[b]错误消息:[/b]
  [b]1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ...[/b]
  [b]...Logical drive configuration has automatically been updated.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  物理驱动器位置发生变化后,逻辑驱动器配置自动更新。
  [b]操作:[/b]
  无需执行任何操作。
  1725 错误消息[b]错误消息:[/b]
  [b]1725-Slot X Drive Array-Optional SIMM Failure Detected[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  由于内存错误或者安装了不支持的 SIMM 类型,SIMM 被自动禁用。
  [b]操作:[/b]
  更换指定控制器上的 SIMM 内存模块。
  1726 错误消息[b]错误消息:[/b]
  [b]1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ...[/b]
  [b]....Array Accelerator configuration has automatically been updated.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  由于更换了具有不同缓存容量的阵列加速器(或控制器),阵列加速器配置自动更新。
  [b]操作:[/b]
  运行 ACU(阵列配置实用程序),更改默认的缓存读/写分配比率。
  1727 错误消息[b]错误消息:[/b]
  [b]1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected...[/b]
  [b]...If more than 32 logical drives, this message will be followed by: Auto-configuration failed: Too many logical drives.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  关闭电源时,控制器检测到连接了其它驱动器阵列。 更新逻辑驱动器配置信息以添加新的逻辑驱动器。 支持的最大逻辑驱动器数量是 32。额外的逻辑驱动器将不能添加至配置中。
  [b]操作:[/b]
  无需执行任何操作。
  1729 错误消息[b]错误消息:[/b]
  [b]1729-Slot 1 Drive Array - Performance Optimization Scan In Progress...[/b]
  [b]...RAID 4/5/ADG performance may be higher after completion.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  RAID 4/5/ADG 奇偶驱动器正在初始化。 ARM(一种在控制器后台运行的自动流程)对奇偶数据进行初始化后,控制器的性能得到改进。
  [b]操作:[/b]
  无需执行任何操作。
  1732 错误消息[b]错误消息:[/b]
  [b]1732-Slot z Drive Array - Array Accelerator Battery Pack Missing...[/b]
  [b]...Array Accelerator Posted-Write Cache is permanently disabled. Array Accelerator will be reenabled when additional battery packs are installed.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  阵列控制器高速缓存电池组从控制器上卸下或者发生故障。
  [b]操作:[/b]
  检查电池组,确保连接牢固。 如果仍出现错误,请更换电池组。
  1733 错误消息[b]错误消息:[/b]
  [b]1733-Slot z Drive Array - Storage Enclosure Firmware Upgrade Problem Detected...[/b]
  [b]...Port x box y: Enclosure firmware upgrade needed - run Flash Components. Port x box y: Unable to read firmware version of one or more components[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  安装了错误的机箱固件版本,或者需要升级机箱固件。
  [b]操作:[/b]
  升级机箱固件和控制器固件。如果问题仍然存在,请更换机箱组件。
  如欲了解更多信息,请参阅惠普网站上的 HP BladeSystem c-Class 机箱故障排除指南 ( http://www.hp.com/support/BladeSystem_Enclosure_TSG_en )。
  1735 错误消息[b]错误消息:[/b]
  [b]1735-Slot z Drive Array - Unsupported Redundant Cabling Configuration Detected...[/b]
  [b]...Multiple paths to the same enclosure/drives are not supported by this Smart Array firmware version. Access to all drives has been disabled until redundant SAS cable(s) are detached, or firmware is updated to a version that supports dual-domain.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  安装了智能阵列固件版本所不支持的冗余布线配置。
  [b]操作:[/b]
  断开冗余 SAS 线缆,然后将智能阵列固件更新至正确的版本。
  1736 错误消息[b]错误消息:[/b]
  [b]1736-HP Trusted Platform Module Error[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  安装了可信平台模块 (TPM),但 System ROM 不能与 TPM 通信。
  [b]操作:[/b]
  从惠普授权的服务提供商请求更换新的系统板和 TPM 板。 安装或更换 TPM 时,请注意下列指导: 不要移除安装的 TPM。 一旦安装,TPM 便成为系统主板的永久部分。安装或更换硬件时,惠普服务提供商不能支持 TPM 或加密技术。 出于安全原因,只有客户才能启用这些功能。将系统主板返回维修更换时,请勿从系统主板上拆除 TPM. 如果请求,惠普服务部门将提供带备用系统板的 TPM。如果尝试从系统主板上移除安装的 TPM,便会折断或损坏 TPM 安全铆钉。 如果发现安装的 TPM 上的铆钉折断或损坏,管理员应考虑系统存在安全隐患,并采取相应的措施确保系统数据的完整性。实用 BitLocker™ 时,务必保留恢复密钥/密码。 BitLocker™ 检测到系统完整性可能受到影响时,需要通过恢复密钥/密码进入“恢复模式”。
  对于 TPM 使用不当造成的无法访问数据,惠普不承担任何责任。 相关操作说明,请参阅随操作系统附带的加密技术特性文档。
  1737 错误消息[b]错误消息:[/b]
  [b]1737-Slot z Drive Array - Redundant Cabling Configuration has excess Device Paths...[/b]
  [b]...Redundant I/O paths to some devices attached to the controller are exceeding per device limit by firmware. These excess paths are ignored.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  冗余布线配置创建的冗余 I/O 路径的数量超过固件允许的数量。
  [b]操作:[/b]
  将固件更新到正确的版本。 检查冗余布线配置。
  1738 错误消息[b]错误消息:[/b]
  [b]1738-Slot z Drive Array - Storage Enclosure Redundant Cabling Problem Detected ...[/b]
  [b]Check storage box I/O module and cable to restore redundant paths to the following disk drive(s):[/b]
  [b]Select “F1” to post this message on reboot if problem persists.[/b]
  [b]Select “F2” to disable this message on reboot if problem persists with logical drive(s) corresponding to these disk drives.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  存储机箱冗余布线存在问题。 发现了之前冗余连接的驱动器的单一路径。
  [b]操作:[/b]
  检查存储机箱 I/O 模块和线缆,以恢复驱动器的冗余路径,然后执行下列某项操作: 如果没有取消冗余线缆或路径,请在重启时按“F1”以显示该消息,直到问题得到解决。 可通过其余的路径访问驱动器。如果取消了冗余路径,请在以后的所有重启中按“F2”禁止该消息。
  1739 错误消息[b]错误消息:[/b]
  [b]1739-Slot z Drive Array - Redundant Cabling Configuration is not as recommended...[/b]
  [b]...Refer to product user guide.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  冗余布线配置错误。
  [b]操作:[/b]
  请参阅用户指南,了解如何以支持的方式对设备进行布线,以获得双域冗余路径支持。
  1742 错误消息[b]错误消息:[/b]
  [b]1742-Slot z Drive Array - Previously Ejected Drive(s) Detected...[/b]
  [b]Select “F1” to continue ignoring these physical drives.[/b]
  [b]Select“F2” to add these physical & logical drive(s) to this controller.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  系统在加电自检期间检测到驱动器仍存在,而用户之前曾请求将该驱动器从控制器配置信息中删除。
  [b]操作:[/b]
  执行以下一项操作: 如果可在稍后删除该驱动器,请按“F1”忽略该物理驱动器。如果要取消删除请求,并将这些物理和逻辑驱动器重新添加至控制器,请按“F2”。
  1743 错误消息[b]错误消息:[/b]
  [b]1743-Slot z Drive Array - Logical Drive Erase Operation in Progress...[/b]
  [b]...Drives being erased are temporarily offline.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  正在擦除的驱动器处于离线状态。
  执行以下一项操作: 使用逻辑驱动器之前,等待擦除流程完成。使用 ACU(阵列配置实用程序)中止擦除流程。
  [b]操作:[/b]
  1744 错误消息[b]错误消息:[/b]
  [b]1744-Slot z Drive Array - Drive Erase Operation Running or Queued...[/b]
  [b]...The following disk drive(s) will be blank upon completion: (followed by a list of drives)[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  用户之前启动了驱动器擦除操作,该操作正在进行当中,或者面向列表中的所有驱动器。
  [b]操作:[/b]
  不需要执行任何操作。
  1745 错误消息[b]错误消息:[/b]
  [b]1745-Slot z Drive Array - Drive Erase Operation Completed...[/b]
  [b]...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled by the Array Configuration Utility: (followed by a list of drives)[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  驱动器擦除操作成功完成,该驱动器处于离线状态,以确保用户再次启用之前,驱动器上无任何内容。
  [b]操作:[/b]
  更换列表中的每个驱动器,或通过下列方法重新启用列表中的每个驱动器: 使用阵列配置实用程序(所有驱动器类型)。执行热插拔移除或重新安装(仅限热插拔硬盘)。
  1746 错误消息[b]错误消息:[/b]
  [b]1746-Slot z Drive Array - Unsupported Storage Connection Detected...[/b]
  [b]...SAS connection via expander is not supported on this controller model. Access to all storage has been disabled. Upgrade controller or detach the expander based storage connections.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  控制器或固件版本不支持连接的驱动器箱。
  [b]操作:[/b]
  升级控制器或者断开基于扩展装置的存储连接。
  1747 错误消息[b]错误消息:[/b]
  [b]1747-Slot z Drive Array - Unsupported Array Configuration Detected...[/b]
  [b]...Followed by one of many possible reasons, including the following:[/b] More logical drives are configured than this controller can support when the memory module is detached.One or more logical drives are configured in positions that this controller does not support when the memory module is detached.One or more logical drives are configured for RAID fault tolerance level(s) that are not supported when the memory module is detached.Configuration information indicates one or more hard drives are located in drive bays that are inaccessible when the memory module is detached.Capacity Expansion operations are pending but cannot continue because the Array Accelerator memory module has been detached.Drive Erase operations are pending but cannot be completed because the Array Accelerator memory module has been detached.ALL logical drives have been disabled. To avoid data loss, re-attach drives to original controller or upgrade controller. To discard all data and create a new configuration, run the Array Configuration Utility.
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  发生了以下情况之一: 阵列加速器内存模块被移除或存在缺陷。驱动器被移动至没有阵列加速器内存模块的控制器。
  [b]操作:[/b]
  将阵列加速器内存模块连接至控制器,或者将驱动器重新移动至原始控制器。 如果容量扩展操作中止,请检查是否连接了原始的阵列加速器模块。
  1748 错误消息[b]错误消息:[/b]
  [b]1748-Slot X Drive Array - Unsupported Array Accelerator Battery Attached...[/b]
  [b]...Please install battery pack(s) with the correct part number.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  阵列加速器缓存模块不支持当前的电池组。
  [b]操作:[/b]
  安装具有正确部件编号的电池组。
  1753 错误消息[b]错误消息:[/b]
  [b]1753-Slot Z Drive Array - Array Controller Maximum Operating Temperature Exceeded During Previous Power Up[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  阵列控制器过热。
  [b]操作:[/b]
  确保为控制器提供充足的散热和气流。
  1754 错误消息 #1[b]错误消息:[/b]
  [b]1754-Slot X Drive Array - RAID ADG configured but ADG is not supported on this controller model.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  该阵列控制器不支持由 ADG 配置的 RAID ADG。
  [b]操作:[/b]
  请更换可支持 RAID ADG 的控制器。
  1754 错误消息 #2[b]错误消息:[/b]
  [b]1754-Slot z Drive Array - One or more RAID levels are configured...[/b]
  [b]...but are not supported due to controller model or an inactive/missing license key. Please re-attach drives to original controller or enter license key.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  控制器型号不支持驱动器上的配置,或者许可密钥未激活或丢失。
  [b]操作:[/b]
  将驱动器重新连接至原始控制器,或者输入有效的许可密钥。
  1757 错误消息[b]错误消息:[/b]
  [b]1757-Slot z Array Accelerator module Incompatible with this controller...[/b]
  [b]...Please replace Array Accelerator module.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  不支持当前的阵列控制器缓存加速器。
  [b]操作:[/b]
  针对该控制器更换正确型号的阵列加速器模块。 如果升级到较大的模块后出现该问题,请在连接新模块之前更新控制器固件。
  1762 错误消息[b]错误消息:[/b]
  [b]1762-Slot X Drive Array - Controller Firmware Upgrade Needed[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  基本控制器和扩展模块控制器上运行不同版本的固件。
  [b]操作:[/b]
  将 SA6400 基本控制器和 SA6400 扩展模块控制器的固件升级到相同的版本。
  1763 错误消息[b]错误消息:[/b]
  [b]1763-Array Accelerator Daughtercard is Detached; Please Reattach[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  阵列加速器模块松动、丢失或存在缺陷。
  [b]操作:[/b]
  重装阵列加速器模块。如果问题仍然存在,请更换阵列加速器模块。
  1764 错误消息[b]错误消息:[/b]
  [b]1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled... (followed by one of the following):[/b]
  [b]...Expansion will resume when Array Accelerator has been reattached.[/b]
  [b]...Expansion will resume when Array Accelerator has been replaced.[/b]
  [b]...Expansion will resume when Array Accelerator RAM allocation is successful.[/b]
  [b]...Expansion will resume when Array Accelerator battery reaches full charge.[/b]
  [b]...Expansion will resume when automatic data recovery has been completed.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  容量扩展流程被暂时禁用。
  [b]操作:[/b]
  按照屏幕上显示的说明操作,恢复容量扩展流程。
  1768 错误消息[b]错误消息:[/b]
  [b]1768-Slot X Drive Array - Resuming Logical Drive Expansion Process[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  执行逻辑扩展操作时断电。 执行阵列扩展时,控制器重置或重启。
  [b]操作:[/b]
  无需执行任何操作。
  1769 错误消息[b]错误消息:[/b]
  [b]1769-Slot X Drive Array - Drive(s) Disabled Due to Failure During Capacity Expansion...[/b]
  [b]...Select F1 to continue with logical drives disabled.[/b]
  [b]...Select F2 to accept data loss and to re-enable logical drives.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  扩展阵列时数据丢失。 因此,驱动器被临时禁用。 由于下列原因造成容量扩展失败: 阵列加速器或硬盘发生故障或被移除。 扩展进程数据丢失。无法从阵列加速器读取扩展进程数据。由于不可恢复的驱动器错误造成扩展流程中止。由于阵列加速器错误造成扩展流程中止。
  [b]操作:[/b]
  按 F2 键接受数据丢失并重新启用逻辑驱动器。从备份中还原数据。更换相应的驱动器或阵列加速器。
  1770 错误消息[b]错误消息:[/b]
  [b]1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...[/b]
  [b]..Please upgrade firmware on the following drive(s) using ROM Flash Components, Model XYZ (minimum version = ####)[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  需要更新驱动器固件。
  [b]操作:[/b]
  指定驱动的固件会造成间歇性问题。 将所有的驱动器更新到最新固件版本。
  点击此处访问业务支持中心下载页面,了解相应的硬盘和存储选项。 .
  1774 错误消息[b]错误消息:[/b]
  [b]1774-Slot X Drive Array - Obsolete Data Found in Array Accelerator[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  驱动器在另外一个控制器上实用并且连接到原始控制器,而此时数据位于原始控制器缓存中。 阵列控制器中的数据比驱动器中的数据旧,并且被自动丢弃。
  [b]操作:[/b]
  检查文件系统以确定数据是否丢失。
  1775 错误消息 #1[b]错误消息:[/b]
  [b]1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:[/b]
  [b]...Check storage system power switch and cables. Turn the system power off while checking the ProLiant power and cable connections, then turn the system power back on to retry.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到存储系统问题。 SCSI 看上去连接至指定的 SCSI 总线,但该总线上未连接驱动器或 SCSI 背板处理器。
  [b]操作:[/b]
  关闭服务器电源。检查外部 ProLiant 电源开关。 启动主系统之前,必须打开所有外部驱动器。确保所有电缆都已正确连接且连接牢固。将存储设备更新到最新固件版本。如果问题仍然存在,请更换线缆、背板或智能阵列控制器。
  1775 错误消息 #2[b]错误消息:[/b]
  [b]1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:[/b]
  [b]...Turn system and storage box power OFF and check cables. Drives in this box and connections beyond it will not be available until the cables are attached correctly.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到存储系统问题。 SCSI 看上去连接至指定的 SCSI 总线,但该总线上未连接驱动器或 SCSI 背板处理器。
  [b]操作:[/b]
  关闭服务器系统和存储箱。确保所有电缆都已正确连接且连接牢固。
  如欲了解布线配置信息,请参阅存储机箱文档。
  1776 错误消息 #1[b]错误消息:[/b]
  [b]1776-Slot X Drive Array - SCSI Bus Termination Error ...[/b]
  [b]Internal and external drives cannot both be attached to the same SCSI port. SCSI port Y: Check cables[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  指定 SCSI 端口的内外部接头连接到驱动器。 问题解决之前,指定 SCSI 总线处于禁用状态。
  [b]操作:[/b]
  当内外部驱动器同时连接到相同的 SCSI 总线时,SCSI 总线未正确连接。请执行下列操作: 关闭服务器电源。确保针对内外部驱动器实用正确的 SCSI 线缆并正确连接。 NOTE: 在某些型号的 ProLiant 服务器上,内部或集成的 SCSI 控制器不能在同一个 SCSI 总线上同时支持内部和外部驱动器。请参阅服务器文档,了解支持的存储配置和布线信息。
  确保所有电缆都已正确连接且连接牢固。重新将驱动器配置到不同的 SCSI 端口。1776 错误消息 #2[b]错误消息:[/b]
  [b]1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I, 1E: Storage connections detected on both shared internal and external ports[/b]
  [b]...Controller selects internal port until connection is removed from one of the ports.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  连接的硬盘布线错误。
  [b]操作:[/b]
  如欲了解布线配置信息,请参阅控制器文档。
  1776 错误消息 #3[b]错误消息:[/b]
  [b]1776-Drive Array Reports Improper SCSI Port 1 Cabling[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  集成的阵列支持板发生故障。I/O 板、驱动器背板风扇板或驱动器背板发生故障。
  [b]操作:[/b]
  更换集成的阵列支持板。将集成的智能阵列选件更新至最新的固件版本。 更换每个选件后请重启服务器: 驱动器背板风扇板驱动器背板系统 I/O 板
  CAUTION: 只有经过惠普培训的授权技术人员才能更换 I/O 板。 如果您认为需要更换 I/O 板,请联系惠普技术支持部门。
  1777 错误消息[b]错误消息:[/b]
  [b]1777-Slot X Drive Array - ProLiant Drive Storage Enclosure Problem Detected... (followed by one or more of the following):[/b]
  [b]SCSI Port Y: Cooling Fan Malfunction Detected[/b]
  [b]SCSI Port Y: Overheated Condition Detected[/b]
  [b]SCSI Port Y: Side-Panel must be Closed to Prevent Overheating[/b]
  [b]SCSI Port Y: Redundant Power Supply Malfunction Detected[/b]
  [b]SCSI Port Y: Wide SCSI Transfer Failed[/b]
  [b]SCSI Port Y: Interrupt Signal Inoperative[/b]
  [b]SCSI Port y: Unsupported ProLiant Storage System Detected[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  驱动器机箱超过环境阙值。
  [b]操作:[/b]
  将手放在风扇上方,检查风扇运转情况。确保塔式服务器或存储系统中的内部散热风扇正常运转。如果风扇不能运转,检查是否发生阻塞,并检查所有内部连接。重新装上设备侧面板。检查 LED 指示灯。 如果 ProLiant 存储系统电源 LED 指示灯为黄色(而不是绿色),则表明冗余电源发生故障。如果出现该消息,请检查 SCSI 线缆: 与 HP Smart Array 控制器用户指南上的图示进行对比。
  如果布线正确,请更换指定端口上的线缆,直到 POST 错误消息消失。
  1778 错误消息[b]错误消息:[/b]
  [b]1778-Drive Array Resuming Automatic Data Recovery Process[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  执行自动数据恢复时,控制器重置或重启。
  [b]操作:[/b]
  无需执行任何操作。
  1779 错误消息[b]错误消息:[/b]
  [b]1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s) now operational:...[/b]
  [b]...Port Y: SCSI ID Z: Restore data from backup if replacement drive X has been installed.[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  容错级别允许的多个驱动器发生故障(或被更换)。 不能重建阵列。 如果没有更换驱动器,则该消息表明发生了间歇性驱动器故障。
  [b]操作:[/b]
  确保总是正确开关系统: 启动系统时,所有外部存储系统必须在服务器之前(或同时)启动关闭系统时,服务器必须在所有外部存储系统之前关闭。
  1783 错误消息[b]错误消息:[/b]
  [b]1783-Slot X Drive Array Controller Failure[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  阵列控制器出现故障。 如果可选 ROMPaq 运行后显示该消息,则说明在尝试更新 ROM 时发生问题。
  [b]操作:[/b]
  重装阵列加速器模块。重装 PCI 插槽中的控制器。将控制器更新到最新固件版本。如果问题仍然存在,请更换控制器。
  1784 错误消息[b]错误消息:[/b]
  [b]1784-Slot X Drive Array Drive Failure. The Following SCSI Drive(s) Should Be Replaced:[/b]
  [b]SCSI Port Y: SCSI ID Z[/b]
  [b]蜂鸣报警:[/b]
  无
  [b]可能原因: [/b]
  检测到存在缺陷的驱动器或 SCSI 线缆。
  [b]操作:[/b]
  确保所有电缆都已正确连接且连接牢固。确保所有驱动器牢固安装。更换存在缺陷的线缆或驱动器 X。
  1785 错误消息[b]错误消息:[/b]
  [b]1785-Slot X Drive Array Not Configured... (followed by one of the following):[/b]
  [b]...(1) Run Array Configuration Utility[/b]
  [b]...(2) No drives detected[/b]
  [b]...(3) Drive positions appear to have changed [/b]
  • 0
    点赞
  • 2
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
HP ProLiant DL380p Gen8服务器用户指南是一本详细介绍了HP DL380p Gen8服务器的使用和管理的指南。该指南旨在帮助用户更好地理解和使用这款服务器。 首先,该指南详细介绍了HP DL380p Gen8服务器的各个组件和功能。它包含了服务器的硬件配置、接口和扩展插槽的位置,以及如何正确连接和安装各种外部设备和组件。 其次,用户指南还提供了服务器的设置和配置方法。它解释了如何设置服务器的基本设置,如日期和时间、网络设置和电源管理。此外,该指南还涵盖了操作系统安装和配置的步骤,以及如何进行RAID配置和硬件故障排除。 此外,指南还详细介绍了服务器的管理功能。它解释了如何使用远程管理工具,如iLO(Integrated Lights Out)来管理服务器,包括远程访问、电源控制和故障诊断等。此外,用户指南还阐述了如何使用HP Insight Control来管理服务器,包括服务器监控、性能优化和虚拟化。 最后,用户指南还包含了一些附录,其中包括服务器规格和兼容性列表,以及常见问题解答和故障排除的建议。 总之,HP ProLiant DL380p Gen8服务器用户指南是一本非常有用的手册,适用于那些使用和管理HP DL380p Gen8服务器的用户。它通过清晰的说明和简单易懂的步骤,帮助用户了解和使用服务器的不同功能和管理工具。无论是初学者还是有经验的管理员,都可以从这本指南中获得有关DL380p Gen8服务器的必要信息。

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值