关于cisco 4507R的主控板卡冗余

这篇博客详细介绍了如何在Cisco 4507R交换机上进行主控板卡的冗余切换操作。通过`redundancy force-switchover`命令强制切换了主处理板卡,并展示了冗余系统的状态,包括系统上线时间、切换次数、备用板卡状态等信息。此外,还展示了切换历史记录和当前的冗余模式。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

切换主处理板卡:redundancy force−switchover

-----------------------------------------------------------------------------------
Cisco4507#show redundancy domain default
Redundant System Information :
------------------------------
       Available system uptime = 9 minutes
Switchovers system experienced = 1
              Standby failures = 0
        Last switchover reason = user forced

                 Hardware Mode = Duplex
    Configured Redundancy Mode = Stateful Switchover
     Operating Redundancy Mode = Stateful Switchover
              Maintenance Mode = Disabled
                Communications = Up

Current Processor Information :
-------------------------------
               Active Location = slot 3
        Current Software state = ACTIVE
       Uptime in current state = 6 minutes
                