mysql主从同步因断电产生的不能同步问题

偶尔因为断电导致mysql slave 出现复制错误“Could not parse relay log event entry”

Could not parse relay log event entry. The possible reasons are: the master's binary log is corrupted (you can check this by running 'mysqlbinlog' on the binary log), the slave's relay log is corrupted (you can check this by running 'mysqlbinlog' on the relay log), a network problem, or a bug in the master's or slave's MySQL code. If you want to check the master's binary log or slave's relay log, you will be able to know their names by issuing 'SHOW SLAVE STATUS' on this slave.

 

先查询下状态

show slave status \G

 

Master_Host: 192.168.2.51

                Master_User: backupuser

                Master_Port: 3306

              Connect_Retry: 60

            Master_Log_File: mysql-bin.000078

        Read_Master_Log_Pos: 984673998

             Relay_Log_File: memcached-relay-bin.000039

              Relay_Log_Pos: 747157846

      Relay_Master_Log_File: mysql-bin.000078

           Slave_IO_Running: Yes

          Slave_SQL_Running: No

 

          Skip_Counter: 0

        Exec_Master_Log_Pos: 747157709

            Relay_Log_Space: 984679197

 

如果可以确定主服务器没有问题的话,那么重置下从服务器的同步位置就可以了。

如上可以对应的指令为:

stop slave;

CHANGE MASTER TO  MASTER_LOG_FILE = 'mysql-bin.000078', MASTER_LOG_POS =747157709;

start slave;

再用 show slave status \G 查看状态。如下:

Master_Log_File: mysql-bin.000078

        Read_Master_Log_Pos: 879029246

             Relay_Log_File: memcached-relay-bin.000002

              Relay_Log_Pos: 1336369

      Relay_Master_Log_File: mysql-bin.000078

           Slave_IO_Running: Yes

          Slave_SQL_Running: Yes

            Replicate_Do_DB: 

        Replicate_Ignore_DB: 

         Replicate_Do_Table: 

     Replicate_Ignore_Table: 

    Replicate_Wild_Do_Table: 

Replicate_Wild_Ignore_Table: 

                 Last_Errno: 0

                 Last_Error: 

               Skip_Counter: 0

        Exec_Master_Log_Pos: 748493843

            Relay_Log_Space: 131871772

            Until_Condition: None

             Until_Log_File: 

              Until_Log_Pos: 0

         Master_SSL_Allowed: No

         Master_SSL_CA_File: 

         Master_SSL_CA_Path: 

            Master_SSL_Cert: 

          Master_SSL_Cipher: 

             Master_SSL_Key: 

      Seconds_Behind_Master: 339469

 

好了到现在搞定了。

还有说法是内存不够用产生的,有人清除了几个不用的进程释放内存后, stop slave; start slave;然后好了,我遇到的不是这个情况,如果你遇到了,按我上面的不能解决的话,可以试着释放内存看看。

 

 

 

 

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值