Oracle/SUN T系列的设备无法加电,报“fault.security.enclosure-open”的错误,如下所示:
show /SP/logs/event/list
Event ID Date/Time Class Type Severity
----- ------------------------ -------- -------- -------- 255 Thu Dec 10 17:06:56 2020 Fault Fault critical
Fault detected at time = Thu Dec 10 17:06:56 2020. The suspect component: /SYS has fault.security.enclosure-open with
probability=100. Refer to
http://support.oracle.com/msg/SPT-8000-AP for details. 254 Thu Dec 10 17:06:56 2020 Fault UUID_Repaired minor
Fault with UUID c1abb80b-38f8-6311-f06c-8968ba403304 repaired 253 Thu Dec 10 17:06:56 2020 Fault Repair minor
Component /SYS repaired 252 Thu Dec 10 17:06:56 2020 Fault Repair minor
Fault fault.security.enclosure-open on component /SYS cleared 251 Sat Jan 1 00:31:38 2000 Fault Fault critical
Fault detected at time = Sat Jan 1 00:31:38 2000. The suspect component: /SYS has fault.security.enclosure-open with
probability=100. Refer to
http://support.oracle.com/msg/SPT-8000-AP for details. 250 Sat Jan 1 00:31:34 2000 Fault UUID_Repaired minor
Fault with UUID e0b17e04-c9fa-cf53-8295-8cae1f9b16bb repaired 249 Sat Jan 1 00:31:34 2000 Fault Repair minor
Component /SYS repaired 248 Sat Jan 1 00:31:34 2000 Fault Repair minor
Fault fault.security.enclosure-open on component /SYS cleared 247 Sat Jan 1 00:29:45 2000 Power Log critical
Host power-on denied because of chassis intrusion. 246 Sat Jan 1 00:29:03 2000 Fault Fault critical
Fault detected at time = Sat Jan 1 00:29:03 2000. The suspect component: /SYS has fault.security.enclosure-open with
probability=100. Refer to
http://support.oracle.com/msg/SPT-8000-AP for details.
拔掉机器电源,重新打开机器的盖板,检查所有线缆,发觉盖板感应器部件的线缆没有连接,如下图所示:
重新接上线缆后,机器可以正常加电。
总结:白色的感应器是用来检测机器上方的盖板的安装情况,如果不能正常检测到上方盖板机器将不能正常加电。