ibm阵列管理webBIOS/MegaCli

http://home.51.com/chenjianghui1987/diary/item/10051836.html


[root@ijxdg2 ~]# dmesg |grep -i raid
dracut: rd_NO_DM: removing DM RAID activation
dracut: rd_NO_MD: removing MD RAID activation
megaraid_sas 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16
megaraid_sas 0000:01:00.0: setting latency timer to 64
megaraid_sas 0000:01:00.0: irq 51 for MSI/MSI-X
scsi0 : LSI SAS based MegaRAID driver
scsi 0:2:0:0: Direct-Access     IBM      ServeRAID M1015  2.12 PQ: 0 ANSI: 5
[root@ijxdg2 ~]# 


[root@ijx ~]# cat /proc/scsi/scsi 
Attached devices:
Host: scsi0 Channel: 02 Id: 00 Lun: 00
  Vendor: IBM      Model: ServeRAID M5015  Rev: 2.12
  Type:   Direct-Access                    ANSI  SCSI revision: 05
Host: scsi5 Channel: 00 Id: 00 Lun: 00
  Vendor: IBM      Model: 1746      FAStT  Rev: 1070
  Type:   Direct-Access                    ANSI  SCSI revision: 05
Host: scsi6 Channel: 00 Id: 00 Lun: 00
  Vendor: IBM      Model: 1746      FAStT  Rev: 1070
  Type:   Direct-Access                    ANSI  SCSI revision: 05


[root@ijx ~]# rpm -vh Lib_Utils-1.00-09.noarch.rpm 
rpm: --hash (-h) may only be specified during package installation
[root@ijx ~]# rpm -ivh Lib_Utils-1.00-09.noarch.rpm 
Preparing...                ########################################### [100%]
Installing....
   1:Lib_Utils              ########################################### [100%]
[root@ijx ~]# rpm -ivh MegaCli-8.02.21-1.noarch.rpm 
Preparing...                ########################################### [100%]
   1:MegaCli                ########################################### [100%]
[root@ijx ~]# 


确认MegaCli包的安装信息
# rpm -ql MegaCli
/opt/MegaRAID/MegaCli/MegaCli
/opt/MegaRAID/MegaCli/MegaCli64
因为安装的是64bit操作系统,所以使用MegaCli64命令。
尝试运行:
#/opt/MegaRAID/MegaCli/MegaCli64
该命令直接执行会提示如下错误
Fatal error – Command Tool invoked with wrong parameters
Exit Code: 0×01
为这个命令做个软连接:
#ln -sf /opt/MegaRAID/MegaCli/MegaCli64 /usr/bin/megacli


4. MegaCli常用命令:
(1)显示所有RAID级别、设置及逻辑盘信息
#megacli -LdInfo -LALL -aAll
(2)显示Raid卡型号,Raid设置,磁盘相关信息
#megacli -cfgdsply -aALL | more
(3)查看RAID卡详细信息
#megacli -AdpAllInfo -aALL
(4)查看适配器个数
#megacli -adpCount
(5)查看逻辑盘个数
#megacli -LdGetNum -aALL
(6)查看电池信息
#MegaCli -AdpBbuCmd -aAll
(7)查看命令帮助
#megacli -help




#megacli -cfgdsply -aALL    【显示Raid卡型号,Raid设置,Disk相关信息】
3.磁带状态的变化,从拔盘,到插盘的过程中。
Device        |Normal|Damage|Rebuild|Normal
Virtual Drive    |Optimal|Degraded|Degraded|Optimal
Physical Drive    |Online|Failed –> Unconfigured|Rebuild|Online


==========================================
[root@ijx ~]# megacli -LdInfo -LALL -aAll
                                     


Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 271.945 GB
Mirror Data         : 271.945 GB
State               : Degraded
Strip Size          : 128 KB
Number Of Drives per span:2
Span Depth          : 2
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disabled
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Is VD Cached: No






Exit Code: 0x00
[root@ijx ~]# 
============================================


ibm x3650   webBios  raid10更换坏的硬盘

拔掉坏硬盘,插入新硬盘。
选中新加硬盘(unconfig ...)-->replace missing pd -->go 
-->Make Online-->go 
-->rebuild drive -->go 







  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值