VB用API获取本机IP地址

Option Explicit

Public Const MIN_SOCKETS_REQD As Long = 1
Public Const WS_VERSION_REQD As Long = &H101
Public Const WS_VERSION_MAJOR As Long = WS_VERSION_REQD \ &H100 And &HFF&
Public Const WS_VERSION_MINOR As Long = WS_VERSION_REQD And &HFF&
Public Const SOCKET_ERROR As Long = -1
Public Const ERROR_SUCCESS As Long = 0
Public Const WSADESCRIPTION_LEN = 257
Public Const WSASYS_STATUS_LEN = 129
Public Const MAX_WSADescription = 256
Public Const MAX_WSASYSStatus = 128
Public Type WSAData
wVersion As Integer
wHighVersion As Integer
szDescription(0 To MAX_WSADescription) As Byte
szSystemStatus(0 To MAX_WSASYSStatus) As Byte
wMaxSockets As Integer
wMaxUDPDG As Integer
dwVendorInfo As Long
End Type
Type WSADataInfo
wVersion As Integer
wHighVersion As Integer
szDescription As String * WSADESCRIPTION_LEN
szSystemStatus As String * WSASYS_STATUS_LEN
iMaxSockets As Integer
iMaxUdpDg As Integer
lpVendorInfo As String
End Type
Public Type HOSTENT
hName As Long
hAliases As Long
hAddrType As Integer
hLen As Integer
hAddrList As Long
End Type
Declare Function WSAStartupInfo Lib "WSOCK32" Alias "WSAStartup" (ByVal wVersionRequested As Integer, lpWSADATA As WSADataInfo) As Long
Declare Function WSACleanup Lib "WSOCK32" () As Long
Declare Function WSAGetLastError Lib "WSOCK32" () As Long
Declare Function WSAStartup Lib "WSOCK32" (ByVal wVersionRequired As Long, lpWSADATA As WSAData) As Long
Declare Function gethostname Lib "WSOCK32" (ByVal szHost As String, ByVal dwHostLen As Long) As Long
Declare Function gethostbyname Lib "WSOCK32" (ByVal szHost As String) As Long
Declare Sub CopyMemoryIP Lib "kernel32" Alias "RtlMoveMemory" (hpvDest As Any, ByVal hpvSource As Long, ByVal cbCopy As Long)

'获取本地IP地址
Public Function GetIPAddress() As String
Dim sHostName As String * 256
Dim lpHost As Long
Dim HOST As HOSTENT
Dim dwIPAddr As Long
Dim tmpIPAddr() As Byte
Dim I As Integer
Dim sIPAddr As String
If Not SocketsInitialize() Then
GetIPAddress = ""
Exit Function
End If
If gethostname(sHostName, 256) = SOCKET_ERROR Then
GetIPAddress = ""
MsgBox "Windows Sockets error " & Str$(WSAGetLastError()) & " has occurred. Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
sHostName = Trim$(sHostName)
lpHost = gethostbyname(sHostName)
If lpHost = 0 Then
GetIPAddress = ""
MsgBox "Windows Sockets are not responding. " & "Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
CopyMemoryIP HOST, lpHost, Len(HOST)
CopyMemoryIP dwIPAddr, HOST.hAddrList, 4
ReDim tmpIPAddr(1 To HOST.hLen)
CopyMemoryIP tmpIPAddr(1), dwIPAddr, HOST.hLen
For I = 1 To HOST.hLen
sIPAddr = sIPAddr & tmpIPAddr(I) & "."
Next
GetIPAddress = Mid$(sIPAddr, 1, Len(sIPAddr) - 1)
SocketsCleanup
End Function

Public Function GetIPHostName() As String
Dim sHostName As String * 256
If Not SocketsInitialize() Then
GetIPHostName = ""
Exit Function
End If
If gethostname(sHostName, 256) = SOCKET_ERROR Then
GetIPHostName = ""
MsgBox "Windows Sockets error " & Str$(WSAGetLastError()) & " has occurred. Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
GetIPHostName = Left$(sHostName, InStr(sHostName, Chr(0)) - 1)
SocketsCleanup
End Function

Public Function HiByte(ByVal wParam As Integer)
HiByte = wParam \ &H100 And &HFF&
End Function

Public Function LoByte(ByVal wParam As Integer)
LoByte = wParam And &HFF&
End Function

Public Sub SocketsCleanup()
If WSACleanup() <> ERROR_SUCCESS Then
MsgBox "Socket error occurred in Cleanup."
End If
End Sub

Public Function SocketsInitialize() As Boolean
Dim WSAD As WSAData
Dim sLoByte As String
Dim sHiByte As String
If WSAStartup(WS_VERSION_REQD, WSAD) <> ERROR_SUCCESS Then
MsgBox "The 32-bit Windows Socket is not responding."
SocketsInitialize = False
Exit Function
End If
If WSAD.wMaxSockets < MIN_SOCKETS_REQD Then
MsgBox "This application requires a minimum of " & CStr(MIN_SOCKETS_REQD) & " supported sockets."
SocketsInitialize = False
Exit Function
End If
If LoByte(WSAD.wVersion) < WS_VERSION_MAJOR Or (LoByte(WSAD.wVersion) = WS_VERSION_MAJOR And HiByte(WSAD.wVersion) < WS_VERSION_MINOR) Then
sHiByte = CStr(HiByte(WSAD.wVersion))
sLoByte = CStr(LoByte(WSAD.wVersion))
MsgBox "Sockets version " & sLoByte & "." & sHiByte & " is not supported by 32-bit Windows Sockets."
SocketsInitialize = False
Exit Function
End If
SocketsInitialize = True
End Function

Sub MAIN()
MsgBox GetIPAddress, , "IP Address"
End
End Sub

  • 0
    点赞
  • 3
    收藏
    觉得还不错? 一键收藏
  • 1
    评论
评论 1
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值