06-01-200801:08 PM
I recently bought an unlocked SPA-3102. I started setting it up to send calls to an Asterisk PBX. I am able to receive incoming calls. I have been unsuccessful in making outbound calls on my PSTN line. My dial plan on the Line 1 tab is: (<#,
xx.<:@gw0>|[2-79]11<:@gw0>|xx.|*xx.|**xx.|<#,
*xx<:@gw0>)
It may be overkill, but I believe it should work. When I dial # and then the number I want to call, I hear one ring and then I get a busy signal. The Last PSTN Disconnect Reason is either CPC Signal or PSTN Disconnect Tone. What can I check to fix this so that I can make outbound calls? I am in the US. Thank you.
-------------------------------------------------------------------
I have seen the problem with my SPA3102. When the SPA3102 takes the FXO port off hook to dial the pstn number it detects a CPC Signal and disconnects the line. The result is as you say.
A CPC signal is a brief interruption of voltage that is used as a signal from a central office that the calling party has hung up. In this case it is a false detection of a CPC signal. You can prove that that is the problem by temporarily disabling detect CPC. I found that I could fix the problem by increasing the Min CPC Duration by 100ms (0.1 sec). I also found that I didn't have the problem if I reversed the two telephone wires so that the voltage was positive instead of negative.
Message Edited by hw on 06-02-2008 08:59 PM
A CPC signal is a brief interruption of voltage that is used as a signal from a central office that the calling party has hung up. In this case it is a false detection of a CPC signal. You can prove that that is the problem by temporarily disabling detect CPC. I found that I could fix the problem by increasing the Min CPC Duration by 100ms (0.1 sec). I also found that I didn't have the problem if I reversed the two telephone wires so that the voltage was positive instead of negative.
Message Edited by hw on 06-02-2008 08:59 PM
------------------------------------------------