adk\src\domains\power\charger_monitor\charger_monitor_config.h
/*! The time to debounce charger state changes (ms).
The charger hardware will have a more limited range. */
#define appConfigChargerStateChangeDebounce() (128)
/*! Trickle-charge current (mA) */
#ifdef QCC3020_FF_ENTRY_LEVEL_AA
#define appConfigChargerTrickleCurrent() (8) /* Adjust for Aura LC RDP to meet battery spec */
#else
#if (defined HAVE_RDP_HW_YE134) || (defined HAVE_RDP_HW_18689)
#define appConfigChargerTrickleCurrent() (30) /* Adjust for Auraplus ANC RDP to meet battery spec */
#else
#define appConfigChargerTrickleCurrent() (10)
#endif
#endif
/*! Pre-charge current (mA)*/
#define appConfigChargerPreCurrent() (MIN(PRE_C