在我国《计算机场地技术条件》国家标准(GB2887—89)中对计算机房内温度、湿度、洁净度的要求如下:
A 级机房内温度、湿度的要求:
| 开机时
| 停机时
| |
温度
| 夏 季
| 冬 季
| 全 年
|
23 ±<chmetcnv wst="on" unitname="℃" sourcevalue="2" hasspace="False" negative="False" numbertype="1" tcsc="0"><span lang="EN-US">2</span>℃</chmetcnv>
| 20 ±<chmetcnv wst="on" unitname="℃" sourcevalue="2" hasspace="False" negative="False" numbertype="1" tcsc="0"><span lang="EN-US">2</span>℃</chmetcnv>
| 5<chmetcnv wst="on" unitname="℃" sourcevalue="35" hasspace="False" negative="True" numbertype="1" tcsc="0">-35<span lang="EN-US"><span lang="EN-US">℃</span></span></chmetcnv>
| |
温度变化率
| <chmetcnv wst="on" unitname="℃" sourcevalue="5" hasspace="False" negative="False" numbertype="1" tcsc="0"><span lang="EN-US" style="FONT-FAMILY: 宋体">5</span> <span style="FONT-FAMILY: 宋体">℃</span> </chmetcnv>/h 并不得结露
| <chmetcnv wst="on" unitname="℃" sourcevalue="5" hasspace="False" negative="False" numbertype="1" tcsc="0"><span lang="EN-US" style="FONT-FAMILY: 宋体">5</span> <span style="FONT-FAMILY: 宋体">℃</span> </chmetcnv>/h 并不得结露
| |
相对湿度
| 45 —65%
| 40% —70%
|
完