酵母生产厂10KV总配电所电气一、二次系统部分设计【设计说明书、CAD图纸、开题报告、实习报告、译文、中期检查表、周记】

目    录

摘  要  ……………………………………………………………1

ABSTRACT  ………………………………………………………2

给定条件……………………………………………………………3

第一章  说明书……………………………………………………4

1.1主接线 ………………………………………………………………4

1.1.1主接线方式 ………………………………………………………4

1.1.2主接线的主要电气设备选择 ……………………………………5

  1. 2负荷计算及无功功率补偿…………………………………………5

1.2.1计算负荷的确定 …………………………………………………5

1.2.2无功功率补偿 ……………………………………………………6

1.3短路电流计算 ………………………………………………………6

1.3.1短路电流的计算方法 ……………………………………………6

1.3.2短路点的确定 ……………………………………………………6

1.4设备选择线路和计量仪表的选择 …………………………………7

1.4.1设备选择 …………………………………………………………7

1.4.2电缆选择 …………………………………………………………9

1.5总配电所布置 ………………………………………………………9

1.5.1布置原则 …………………………………………………………9

1.5.2布置方案…………………………………………………………10

1.6继电保护……………………………………………………………11

1.6.1继电保护的任务和要求…………………………………………11

1.6.2高压侧线路保护…………………………………………………11

1.6.3变压器保护………………………………………………………12

1.7配电所接地和防雷…………………………………………………13

第二章  计算书 …………………………………………………14

2.1负荷计算……………………………………………………………14

2.2短路电流计算………………………………………………………17

2.3设备的选择计算及校验……………………………………………19

2.3.1高压设备…………………………………………………………19

2.3.2低压设备…………………………………………………………24

2.4继电保护……………………………………………………………30

2.4.1高压侧线路保护…………………………………………………30

2.4.2变压器保护………………………………………………………32

2.5接地装置计算………………………………………………………33

参考文献 ………………………………………………………………34

附表 ……………………………………………………………………35

附图 ……………………………………………………………………35

致谢 ……………………………………………………………………36

摘  要

                                

电力配电站是由一系列设备组成的电力系统,电能在其中转换、分配、联络、变压、转换。一个配电站包括各类设备:变压器、断路器、负荷开关、母线、电流互感器、电压互感器等。

配电站是一种综合设施,它可以从分支输电网到初级配电网对电压进行切换和调节。最重要的是,由于配电站的存在,一部分配电站设备的损坏,或一条通向配电站的电缆切断,都不会引起全局的供电故障。

本文是对10千伏变电站电气部分的设计。在设计中,我们运用经济及技术比较的方法来确定变电站的电气主接线,运用短路电流实用计算法来进行短路电流计算。通过查阅设计手册和技术规程对主要设备和导体以及电气总平面布置和高压配电装置进行了设计和选择。

该变压室设有2台主变压器,采用单母线结构及单母线分段的结构。进行了电气主接线图形式的论证、短路电流计算、主要电气设备选择及校验(包括断路器、负荷开关、隔离开关、电流互感器、电压互感器),同时介绍了继电保护的设计整定等相关方面的知识。

关键词:10KV变配电站  短路电流  变压器  继电保护

                                   

ABSTRACT

       

The electric power substation is an assembly of equipment in an electric power system through which electrical energy is passed for transmission, distribution, interconnection, transformation, or switching. A substation includes a variety of equipment: transformers, circuit breakers, load break switch, bus-bars, current transformers, potential transformers, and so on.                     

The distribution substation is an assemblage of equipment for purpose of switching, changing, and regulating the voltage from subtranmission to distribution. More important substations are designed so that the failure of a piece of equipment in the substation or one of the subtranmission lines to the substation will not cause an interruption of power to the load.

This paper introduces the design of main electricity system about the 10KV substation,and return fish-eye an electricity lord to connect the line diagram to take into the elucidation at the same time. We utilize the means of economy and technology comparing to select main electricity connect of the 10KV substation, and compute short current by the means of practical short current’s compute in the design . We design and select main equipment and conductor、plant network、plan of site and high voltage distribution equipment through checking designing handbook and technical code .

That transformer substation has two main transformer of sets,choose single bus-bar structure.And return fish-eye an electricity lord、short current、choice and check of main equipment(include circuit breaker、load break switch、disconnect switch、current transformer、potential transformer ),introduce the relay protection and so on .

Key words: 10KVdistribution substation; short current; transformers; relay protection

…………

…………