为了试验目的它展示了2种交换机的配置方法,以下是其中一种,N5K作为NPV模式,MDS交换机不需要指定端口速率模式,端口默认模式是trunk,允许所有VSAN
DC2-MDS-1
feature npiv
vsan database
vsan 100 name vsan100
vsan 100 interface fc1/1
switchport mode F
switchport trunk mode off
no shut
DC2-N5K-1
feature fcoe
feature npv
vsan database
vsan 100 name vsan100
vsan 100 interface fc 1/31
interface fc 1/31
switchport mode np
switchport trunk mode off
no shut
sho npv status
-----------------------------
以下是第二种配置方法,MDS交换机需要指定速率模式,端口模式为e
DC2-MDS-1
vsan database
vsan 200 name vsan200
interface fc1/5
switchport rate-mode dedicated
switchport mode e
switchport trunk mode on
switchport trunk allow vsan 200
no shut
DC2-N5K-2
feature fcoe
vsan database
vsan 200 name vsan200
interface fc1/31
switchport mode e
switchport trunk mode on
switchport trunk allow vsan 200
no shut
sho int fc1/31
-------------------------------
配置DC2-MDS-1 到 DC1-MDS-1链路 端口模式为e
DC2-MDS-1
interface fc1/7
switchport rate-mode dedicated
switchport mode e
no shut
配置DC1-MDS-1交换机
vsan database
vsan 100 name vsan100
vsan 200 name vsan200
exit
interface fc1/7
switchport rate-mode dedicated
switchport mode e
no shut
sho int fc1/7
-------------------------------------
配置DC1-MDS-1 与 open-e互联口
DC1-MDS-1
vsan database
vsan 100 interface fc1/10
vsan 200 interface fc1/11
interface fc1/10-11
no shut
sho flogi database
查看注册信息
---------------------------------------
配置esxi1与N5K-1和N5K-2互联口 端口模式需要改为F口
DC2-N5K-1
vsan database
vsan 100 interface fc1/30
interface fc1/30
switchport mode f
no shut
DC2-MDS-1 : sho flogi database
DC2-N5K-2
vsan database
vsan 200 interface fc1/30
interface fc1/30
switchport mode f
no shut
sho flogi database
----------------------------------------
配置 esxi2与DC2-MDS-1,注意这里只配置了1条链路是试验为了和esxi1做对比
DC2-MDS-1
vsan database
vsan 100 inteface fc1/3
switchport mode f
no shut
sho flogi database
-----------------------------------------
在任意一台交换上
DC1-MDS-1配置ZONE,注意这一步不是必须,只是为了简化名称配置,只需要配置esxi和共享存储端口,中间交换机不管
device-alias database
device-alias name esxi1to5k1 pwwn 21:00:00:1b:32:11:53:36
device-alias name esxi1to5k2 pwwn 21:01:00:1b:32:11:53:36
device-alias name esxi2tomds pwwn 21:00:00:1b:32:07:99:e7
device-alias name openefc10 pwwwn 21:00:00:1b:32:11:4d:33
device-alias name openefc11 pwwwn 21:01:00:1b:32:11:4d:33
device-alias commit
zone name zone_vsan100 vsan 100
member device-alias esxi1to5k1
member device-alias esxi2tomds
member device-alias openefc10
zoneset name zs_vsan100 vsan 100
exit
zoneset activate name zs_vsan100 vsan 100
sho zone active
zone name zone_vsan200 vsan 200
member device-alias esxi1to5k2
member device-alias openefc11
zoneset name zs_vsan200 vsan 200
exit
zoneset activate name zs_vsan200 vsan 200
sho zoneset avtice vsan 200
-----------------------------------------
接下来操作共享存储 open-e 光纤通道选择T模式;创建FC卷 ; FC目标管理器,创建卷组,添加卷;映射卷组到WWN
最后操作esxi 磁盘管理 指定为闪存类型;数据存储,添加存储;连接和多路径改成循环做路径高可用。